On , OSHA opened a complaint safety inspection of H. C. COLEMAN & COMPANY INC. in 706 IVY STREET, DEMOREST, GA 30535 (NAICS 236220). OSHA activity number 339982456.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- H. C. COLEMAN & COMPANY INC.
- Site address
- 706 IVY STREET
- City
- DEMOREST
- State
- GA
- ZIP
- 30535
- Mailing
- 939 N. COBB PKWY SUITE 108, MARIETTA, GA 30062
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 45
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1926.701 B
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $5,390 · Current $3,234 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: On or about 10/03/14 at 706 Ivy Street, Demorest, GA. The employer failed to provide re-bar caps for all the protruding reinforcing steel for clarifier # 1 that was under construction.
Recent events (2)
- · I (S) $3234
- · Z (S) $5390
1926.1053 B01
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $5,390 · Current $3,234 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder. On or about 10/03/14 at 706 Ivey Street, Demorest, GA , GA: Employees were exposed to fall hazards, while performing painting work, employees were using a portable ladder to gain access into clarifier # 1, and the ladder was only 8 inches above the landing surface.
Recent events (2)
- · I (S) $3234
- · Z (S) $5390
1926.1412 E03 I
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $5,390 · Current $3,234 Reduced
General-duty citation text
29 CFR 1926.1412(e)(3)(i): The following information must be documented and maintained by the employer that conducts the inspection: On or about 10/03/14 at 706 Ivy Street, Demorest, GA : The employer failed to document and retain for the following: services, inspections, repairs, corrective actions, items checked, name of person conducted the inspection and the date.
Recent events (2)
- · I (S) $3234
- · Z (S) $5390
1926.1427 B02
- Issued
- Oct 23, 2014
- Abate by
- Nov 19, 2014
- Penalty
- Initial $4,620 · Current $0 Reduced
General-duty citation text
29 CFR 1926.1427(b)(2): An operator will be deemed qualified to operate a particular piece of equipment if the operator is certified under paragraph (b) of this section for that type and capacity of equipment or for higher-capacity equipment of that type. If no accredited testing agency offers certification examinations for a particular type and/or capacity of equipment, an operator will be deemed qualified to operate that equipment if the operator has been certified for the type/capacity that is most similar to that equipment and for which a certification examination is available. The operator's certificate must state the type/capacity of equipment for which the operator is certified. On or about 10/03/14 at 706 Ivy Street, Demorest, GA: Employer failed to have the superintendent trained and certified prior to operating the cranes on the job sites
Recent events (2)
- · I (S) $0
- · Z (S) $4620
More inspections at H. C. Coleman & Company INC.