OSHA Inspection: ANDREW MILLER

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANDREW MILLER in 2020 EDINBORO ROAD, ERIE, PA 16509 (NAICS 238130). OSHA activity number 339983041.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Andrew Miller — free Get an email when a new federal OSHA severe-injury report for Andrew Miller is published. One employer, no account, unsubscribe in one click.
Establishment
ANDREW MILLER
Site address
2020 EDINBORO ROAD
City
ERIE
State
PA
ZIP
16509
Mailing
9285 NORTH PARK AVENUE, NORTH BLOOMFIELD, OH 44450
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 7, 2014
Abate by
Dec 5, 2014
Penalty
Initial $1,600 · Current $1,600
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:  A.)  Andrew Miller dba A.M. Carpentry, 2020 Edinboro Road, Erie, PA  16509, first floor, on or about October 2, 2014 and times prior thereto, employees were exposed to impalement hazards from bolts that protrude from the concrete floor.  Employees on-site were performing work duties including, but not limited to, accessing a ladder located on the first floor of the structure to access the second floor, and taking lunch breaks on the first floor of the structure.  One-half inch bolts were cemented into the concrete floor, and protruded 2-3 inches out of the concrete floor to secure wood stud wall structures to the first floor.  The protruding bolts were not protected by impalement protection, including, but limited to, caps, cover and troughs.
Recent events (1)
  • — Z (S) $1600

1926.501 B01

Serious Gravity 10 3 instances 3 exposed
Issued
Nov 7, 2014
Abate by
Dec 5, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:  A.)  Andrew Miller dba A.M. Carpentry, 2020 Edinboro Road, Erie, PA  16509, north side of second floor, on or about October 2, 2014 and times prior thereto:  Employees were performing construction tasks on the second floor of the building including, but not limited to, setting exterior walls and performing carpentry tasks.  A guardrail system was installed on the south side of the second floor, but did not continue around to the north side of the second floor exposing employees to a 10.25-feet fall hazard.  Employees were not otherwise protected by a means or method of fall protection including, but not limited to, a completed guardrail system, a safety net system, or personal fall arrest systems  B.)  Andrew Miller dba A.M. Carpentry, 2020 Edinboro Road, Erie, PA  16509, east side of second floor, on or about October 2, 2014 and times prior thereto:  Employees were performing construction tasks on the second floor of the building including, but not limited to, setting exterior walls and performing carpentry tasks.  A complete guardrail system was not constructed on the east side of the building.  The guardrail system contained gaps including, but were not limited to, an 11-inch gap, 18-inch gap, and 23-inch gap, in which employees could pass through.  These gaps exposed employees to a 10.25-feet fall hazard.  Employees were not otherwise protected by a means or method of fall protection including, but not limited to, a completed guardrail system, a safety net system, or personal fall arrest systems.  C.)  Andrew Miller dba A.M. Carpentry, 2020 Edinboro Road, Erie, PA  16509, south side of second floor, on or about October 2, 2014 and times prior thereto:  Employees were performing construction tasks on the second floor of the building including, but not limited to, setting exterior walls and performing carpentry tasks.  A guardrail system was installed on the south side of the second floor, but was constructed one-foot from the floor edge.  As a result, a one-foot gap existed between the floor edge and guardrail system through which employees could fall.  The condition exposed personnel to a fall hazard of 10.25-feet. Employees were not otherwise protected by a means or method of fall protection including, but not limited to, a safety net system or personal fall arrest systems.
Recent events (1)
  • — Z (S) $2800

1926.501 B14

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 7, 2014
Abate by
Dec 5, 2014
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.501(b)(14): Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system:  A.) Andrew Miller dba A.M. Carpentry, 2020 Edinboro Road, Erie, PA  16509, southwest side of second floor, on or about October 2, 2014 and times prior thereto:  Employees were setting exterior walls on the southwest side of the structure's second floor.  The exterior wall was equipped with a 48-inch by 60-inch wall opening for a window.  Employees setting the wall where the wall opening existed were not utilizing a means or method of fall protection including, but not limited to, personal fall arrest systems (PFAS), guardrail systems, or safety net systems when exposed to a 10.25-feet fall hazard.