PENNSAUKEN, NJ ·
OSHA Inspection: RIVER ROAD RECYCLING
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of RIVER ROAD RECYCLING in 450 37TH STREET, PENNSAUKEN, NJ 08110 (NAICS 423930). OSHA activity number 339989113.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RIVER ROAD RECYCLING
- Site address
- 450 37TH STREET
- City
- PENNSAUKEN
- State
- NJ
- ZIP
- 08110
- Mailing
- 450 37TH STREET, PENNSAUKEN, NJ 08110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 16
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.24 B
- Issued
- Jan 13, 2015
- Abate by
- Feb 9, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: a) Baler Area: Fixed stairs were not provided to access the baler platform, on or about 10/16/14. b) Baler Area: Fixed stairs were not provided to access the baler, on or about 10/16/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.26 C02 VII
- Issued
- Jan 13, 2015
- Abate by
- Feb 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.26(c)(2)(vii): Ladders having defects were not marked and taken out of service until repaired. a) Baler Area: An employee climbed up a Davidson 6' ladder that was missing a rear rail and braces to perform maintenance on the baler, on or about 10/16/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.146 C01
- Issued
- Jan 13, 2015
- Abate by
- Feb 9, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a) Baler Area: The employer did not conduct identify confined spaces, such as but not limited to the baler, on or about 10/7/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1910.146 C02
- Issued
- Jan 13, 2015
- Abate by
- Feb 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(c)(2): The employer did not inform exposed employees, by posting danger signs or by any other equally effective means, of the existence and location of and the danger posed by the permit spaces: a) Baler: The employer did not post danger signs of the danger posed by entering the baler, on or about 10/7/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.146 C04
- Issued
- Jan 13, 2015
- Abate by
- Mar 15, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: a) Baler Area: The employer did not develop a written permit space entry program for employees that were required to enter confined spaces such as, but not limited to the baler, on or about 10/7/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1910.147 C01
- Issued
- Jan 13, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Baler Area: The employer did not develop a hazardous energy control program consisting of an energy control procedure, employee training and periodic inspections to ensure employees safety before performing any servicing or maintenance on equipment such as but not limited to the baler, on or about 10/7/14 NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1910.178 L02 II
- Issued
- Jan 13, 2015
- Abate by
- Mar 1, 2015
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. Facility: Powered industrial vehicle operators that operated vehicles such as but not limited to Toyota Forklift Truck 81 C030, Nissan 70 Forklift Truck model MYO1F2A35 and a stand up fork truck (No Id) were not given training consisting of formal instruction of the operators performance in the workplace, on or about 10/7/14. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1910.212 A01
- Issued
- Jan 13, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Baler Area: Rotating parts from a fan on top of the baler were not guarded, on or about 10/7/14. b) Baler Area: Rotating wheels on the side of the baler were unguarded creating an ingoing nip point, on or about 10/7/14
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1910.305 B01 II
- Issued
- Jan 13, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. a) Baler Area: The control panel for the baler had an opening that was not closed, on or about 10/7/14 b) Baler Area: The cover of the electrical panel for the baler had an opening that was not closed, on or about 10/7/14.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.305 G01 IV B
- Issued
- Jan 13, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and/or cables were run through holes in walls, ceilings, or floors: a) Weighing Area: A flexible cord was run from the indoor weighing area through a hole in the wall to the outside weighing area, to power a weight scale, on or about 10/7/14.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1910.305 G02 II
- Issued
- Jan 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap: a) Weighing Area: A power cord for the scale was spliced, on or about 10/7/14.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 423930)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339989113.