BELTON, TX —
OSHA Inspection: AMERICAN SPINCAST, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMERICAN SPINCAST, INC. in 2505 TAYLORS VALLEY RD., BELTON, TX 76513 (NAICS 331513). OSHA activity number 339991119.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN SPINCAST, INC.
- Site address
- 2505 TAYLORS VALLEY RD.
- City
- BELTON
- State
- TX
- ZIP
- 76513
- Mailing
- P.O. BOX 769, BELTON, TX 76513
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331513
- Employees
- 70
- Ownership type
- A
Citations
49 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: the employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of falling with and/or being struck by a shop-built lift basket used to lift personnel on the forks of forklifts. On or about October 8, 2014, and at times prior thereto, the employer provided a shop built personnel basket for use with multiple forklifts of different manufacturers without ensuring the design was compatible with each forklift configuration. Among other defects, the basket was not equipped with a secure means of attachment, was longer than the forks of the forklift, and was not equipped with a midrail.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.22 B01
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $500 Reduced
General-duty citation text
29 CFR 1910.22(b)(1): Aisles and passageways were not kept clear and in good repair, with no obstruction across or in aisles that could create a hazard. On or about October 8, 2014 and at times prior thereto, the employer did not ensure that floors and passageways were kept in good repair: a. In the foundry on the stairs leading to furnaces G and H, there was a gap between the stairs and elevated floor causing a tripping hazard. b. In the Saw Department, the floors were damaged in the main walkway leading to the saws, causing a tripping hazard.
Recent events (2)
- — I (S) $500
- — Z (S) $2100
1910.24 F
- Issued
- Apr 6, 2015
- Abate by
- May 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs: On or about October 8, 2014, and at times prior thereto, the stairs leading to furnaces G and H did not have uniform rise height, exposing employees to the hazards of slips, trips and falls.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.23 C01
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open sided floor(s) or platform(s) 4 feet or more above the adjacent floor or ground level were not guarded by standard railings (or the equivalent as specified in 29 CFR 1910.23(e)(3)(i) through (v)), on all open sides: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that the open sided floor on the bag house located outside next to the Shot Blast Department was guarded by a standard railing, exposing employees to a fall hazard of approximately 5 feet.
Recent events (2)
- — I (S) $1000
- — Z (S) $2800
1910.27 D03
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.27(d)(3): The side rails and rungs of side step ladders did not continue a minimum of 3 1/2 feet above the landing platform: On or about October, 8, 2014, and at times prior thereto, the employer did not ensure that the fixed ladder installed for use to access the bag house platform was constructed so the side rails extended 3 1/2 feet above the landing, exposing employees to a fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 A03
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $750 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not free and/or unobstructed. On or about October 8, 2014, and at times prior thereto, at the bottom of the stairs leading from the Foundry to the Shipping Department there were pallets, extension cords and a DeWalt Circular Saw blocking the egress route, exposing employees to hazards of slips, trips, and falls in the event of fire.
Recent events (2)
- — I (S) $750
- — Z (S) $2100
1910.37 A04
- Issued
- Apr 6, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that emergency lighting systems for the whole facility were tested and maintained in working order, exposing employees to the hazards of fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $750 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit.": On or about October 8, 2014, and at times prior thereto, the employer did not ensure that exits were marked with exit signs, exposing employees to entrapment and/or delayed escape in the event of fire. a. In the foundry, the exit door on the west side wall next to the bay door was not marked with an exit sign. b. In the maintenance shop on the north end of the facility, the exit door next to the bay door was not marked with an exit sign. c. The door leading from the CNC Department to the Machine Shop was not marked with an exit sign indicating the path of travel to the nearest exit. d. In the machine shop on the north end of the facility, the exit door next to the bay door was not marked with an exit sign.
Recent events (2)
- — I (S) $750
- — Z (S) $2100
1910.37 B06
- Issued
- Apr 6, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that three exit signs were illuminated, exposing employees to the hazards of fire. a. The exit leading from the foundry floor to the shipping department. b. The exit leading from the machine shop to the heat treat department. c. The exit leading from the CNC Department to the outside.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.132 A
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $4,200 · Current $4,200
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that employees were provided with fall protection equipment while performing work on top of elevated work locations. a. In the Shot Blast Department, employees were required to access the top of the shot blast booth to perform work, exposing employees to a fall hazard of approximately 10 feet. b. In the Heat Treat Department, employees were required to access the top of 5 ovens to perform work, exposing employees to a fall hazard of up to approximately 11 feet.
Recent events (2)
- — I (S) $4200
- — Z (S) $4200
1910.147 C04 I
- Issued
- Apr 6, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section. On or about October 8, 2014, employees were exposed to the hazards associated with unexpected start-up of machines in that specific, written Lockout/Tagout procedures were not developed and utilized for equipment/machines such as but not limited to the following: a. In the CNC Department, the #1 Seiki CNC Lathe, Type 4NE, Serial # NE-41538. b. In the CNC Department, the #2 Cadet CNC Lathe, Model L1420, Serial # 09040462 c. In the CNC Department, the #3 Mori Seiki CNC Lathe, Model SL-7. d. In the CNC Department, the #4 Mori Seiki CNC Lathe, Model LL-7. e. In the CNC Department, the #6 Hwacheon CNC Lathe, Model HI-ECO-45, Serial #M073347D1IA. f. In the Saw Department, Saw #1. g. In the Saw Department, Saw #2. h. In the Saw Department, Saw #3. I. In the AmStock Department, the AmStock Saw.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.147 C07 I A
- Issued
- Apr 6, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that each employee performing maintenance on machines and equipment had received training on all methods and means necessary to control hazardous energy sources, exposing employees to the hazards of being struck by and/or caught in machines, or receiving electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $500 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. On or about October 8, 2014, and at times prior thereto, the employer did not ensure that portable fire extinguishers were readily available for employee use, exposing employees to the hazards of fire. a. In the Shipping Department on the east wall the portable fire extinguisher was missing and not mounted. b. In the Metal Storage/Charge Area on the column next to the control panels the portable fire extinguisher was missing and not mounted. c. In the Foundry Area on the south wall the portable fire extinguisher was blocked by cardboard drums. d. In the Machine Shop the fire extinguisher located in the small maintenance shop at the south end was blocked by sheets of plywood and a red 55 gallon drum.
Recent events (2)
- — I (S) $500
- — Z (S) $2100
1910.157 G01
- Issued
- Apr 6, 2015
- Abate by
- May 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting. On or about October 8, 2014, and at times prior thereto, the employer did not ensure that employees were trained on the principles of fire extinguisher use and the hazards involved with incipient stage fires, exposing employees to the hazards of fires.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Apr 6, 2015
- Abate by
- Apr 23, 2015
- Penalty
- Initial $2,100 · Current $500 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about October 8, 2014, and at times thereafter, in the Shot Blast Area, the employer did not ensure that each employee operating a forklift received training and evaluation, exposing employees to the hazards of being struck by forklifts.
Recent events (2)
- — I (S) $500
- — Z (S) $2100
1910.179 H04
- Issued
- Apr 6, 2015
- Abate by
- May 30, 2015
- Penalty
- Initial $3,500 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.179(h)(4): Hooks did not meet the manufacturer's recommendations: On or about October 8, 2014, and at times prior thereto, the employer did not ensure the hooks were used in accordance with the manufacturer's recommendations, exposing employees to the hazard of being struck by falling loads in the event the hook should fail. a. On the 2 Ton Bridge Crane located on the south end of the Machine Shop the hook's clasp was too large not allowing it to close to keep the sling inside the hook. b. On the 2 Ton Bridge Crane located on the north end of the Machine Shop the hook's clasp was sprung allowing a sling to roll out and drop the load.
Recent events (2)
- — I (S) $1500
- — Z (S) $3500
1910.179 N04 I
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $4,900 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.179(n)(4)(i): The upper limit switch of each hoist was not tried out under no load, at the beginning of each operator's shift: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that the upper limit switch of the crane hoists had been tried out under no load daily on the following cranes, exposing employees to the hazard of being struck by/crushed by crane parts and their loads in the event the crane should fail. a. In the spinner department Crane #1 Shawbox 800. b. In the metal storage area Crane #2 Chester Mod#WDMT-161. c. In the spinner department Crane #3 Chester, Model #WDMT1103S. d. In the mold storage area Crane #4 Chester , Model #72L05026S151R. e. In the saws department Crane #5 Shawbox, Model #80L03030S181R. f. In the north end of the machine shop Crane #6 Shawbox, Model #80L02020S14. g. In the south end of the machine shop Crane #7 Shawbox, Model #80L02020S14. h. In the end plate area Crane #8 Shawbox, Model #WB3M25STK. I. Next to the melt deck G & H Crane #9 Demag, EKP 212H11L4-1. j. In the shipping department Crane #10 Chester, Model #WDMT-161. k. In the CNC department Crane #11 Shawbox, Model #80L02020S14.
Recent events (2)
- — I (S) $2000
- — Z (S) $4900
1910.184 C02
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $3,500 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.184(c)(2): Makeshift device(s), knot(s) or bolt(s) were used to shorten sling(s) On or about October 8, 2014, and at times prior thereto, the alloy steel sling used in the AmStock Department was shortened with two blocks of wood, exposing employees to the hazards of being struck by/crushed by falling loads in the event the sling should break.
Recent events (2)
- — I (S) $1500
- — Z (S) $3500
1910.184 D
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $4,900 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.184(d): Sling(s) and fastenings were not inspected by a competent person each day, before being used, for damage or defects: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that alloy steel chain slings and synthetic web slings throughout the facility were inspected prior to daily use, exposing employees to the hazards of being struck by falling loads in the event the slings should fail.
Recent events (2)
- — I (S) $2000
- — Z (S) $4900
1910.184 E01
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel chain slings did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: On or about October 8, 2014, and at times prior thereto, the employer did not ensure alloy steel chains used to lift loads such as molds and castings had identification tags that were legible and installed on the slings, exposing employees to the hazards of being struck by falling loads.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 E03 I
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(e)(3)(i): Thorough periodic inspections of alloy steel chain slings in use were not made on a regular basis: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that alloy steel chain slings used throughout the facility were inspected on a regular basis for damage or defects, exposing employees to the hazard of being struck by falling loads in the event a sling should fail.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.184 E06
- Issued
- Apr 6, 2015
- Abate by
- Jun 15, 2015
- Penalty
- Initial $3,500 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.184(e)(6): Alloy steel chain slings were not permanently removed from service if they are heated above 1000 degrees F. On or about October 08, 2014, and at times prior thereto, alloy steel chain slings were wrapped around castings that are heated to 1400 degrees F and were not removed from service.
Recent events (2)
- — I (S) $1500
- — Z (S) $3500
1910.184 I01
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $4,900 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material: On or about October 8, 2014, and at times prior thereto, the employer did not ensure that the Synthetic web sling(s) utilized in both the Machine Shop and CNC Department were marked or coded to show their rated capacities, exposing employees to the hazards of being struck by/crushed by falling loads.
Recent events (2)
- — I (S) $2000
- — Z (S) $4900
1910.184 I09 IV
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(i)(9)(iv): Synthetic web sling(s) with broken or worn stitches were not immediately removed from service: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that synthetic web slings with broken or worn stitches used in the CNC department and the machine shop were removed from service, exposing employees to the hazard of being struck by falling loads.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $4,900 · Current $4,900
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about October 8, 2014, and at times prior thereto, the employer did not provide machine guards to the following equipment, exposing the employees to the hazards of being caught in rotating parts. a. In the Metal Storage Area on the grinding wheel, the guard was loose and not covering the grinding wheel. b. In the Metal Storage Area on the Jet Belt Sander and Disc Grinder, the bottom work rest and guard were missing. c. In the Machine Shop on Standard Lodge & Shipley lathe #21, the chuck guard cover was not installed on the lathe. d. In the Machine Shop on lathe #35, the chuck guard cover was not lowered into position while the operator was running the lathe. e. In the Machine Shop on lathe #38, the chuck guard cover was missing. f. In the Heat Treat Department on the HEM Saw, the saw did not have guards installed over the non-working portion of the blade. g. In the CNC Department on the #2 Cadet CNC machine Model #L1420, interlocks had been by-passed, permitting access to the rotating chuck. h. In the CNC Department on the #6 Hwacheon CNC machine Model #Hi-ECO-45, interlocks had been by-passed, permitting access to the rotating chuck. i. In the CNC Department, on the #4 Moriseiki LL-7, the Chip Conveyor belt was missing the guard cover over the ends of the ejection area. j. In the CNC Department on the #3 Moriseiki SL-7, the Chip Conveyor belt was missing the guard cover over the ends of the ejection area.
Recent events (2)
- — I (S) $4900
- — Z (S) $4900
1910.212 A03 II
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): On or about October 08, 2014, and at times prior thereto, the employer did not ensure that the Bridgeport Milling machine had a point of operation guard installed, exposing employees to the hazard of being caught in the rotating cutter.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A05
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $500 Reduced
General-duty citation text
29 CFR 1910.212(a)(5): Fan blade guards, where the periphery of the blades was less than seven feet above the floor or working level, had openings larger than one half inch: On or about October 08, 2014, and at times prior thereto, the portable TPI industrial floor fan guard had openings up to 1 1/4 inch, exposing employees to the hazard of being struck by the rotating blade.
Recent events (2)
- — I (S) $500
- — Z (S) $2100
1910.212 B
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $500 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that the Furnas heavy-duty shear was securely anchored to prevent walking or moving, exposing employees to the hazard of being struck by the machine.
Recent events (2)
- — I (S) $500
- — Z (S) $2100
1910.215 B09
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that the distance between the abrasive wheel periphery(s) and the adjustable tongue at the top did not exceed one fourth inch, exposing employees to the hazards of being struck by flying wheel fragments in the event of wheel breakage. a. In the Machine Shop along the west wall the Jet Equipment & Tools 6 inch bench grinder, adjustment on left side 1/2 inch. b. In the Machine Shop along the east wall the Jet Equipment & Tools 6 inch bench grinder, adjustments left side 1/2 and right side 1 inch. c. In the Maintenance Shop the Jet Equipment & Tools 10 inch bench grinder, left side approximately 1 1/2 inch.
Recent events (2)
- — I (S) $1000
- — Z (S) $2100
1910.219 C02 I
- Issued
- Apr 6, 2015
- Abate by
- May 30, 2015
- Penalty
- Initial $4,900 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about October 08, 2104, and at times prior thereto, the employer did not ensure that the horizontal shafts on the three shop-built saws in the Saw Department and one in the AmStock Department were protected by a stationary casing, exposing employees to the hazard of being caught in the rotating shafts.
Recent events (2)
- — I (S) $2500
- — Z (S) $4900
1910.219 C04 I
- Issued
- Apr 6, 2015
- Abate by
- May 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends did not present a smooth edge and end and projected more than one-half the diameter of the shaft without being guarded by nonrotating caps or safety sleeves. On or about October 08, 2014, and at times prior thereto, the employer did not ensure that projecting shaft ends on three saws in the Saw Department and one in the AmStock Area were guarded with a non-rotating cap or safety sleeve, exposing employees to the hazard of being caught in the rotating shaft ends.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Apr 6, 2015
- Abate by
- May 30, 2015
- Penalty
- Initial $4,900 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): On or about October 08, 2014, and at times prior thereto, the employer did not ensure that belts and pulleys were guarded, exposing employees to the hazards of being caught in belt/pulley pinch points. a. Vertical lathe #41 in the Machine Shop, guards were missing on the main power drive belts and pulleys on the back of the lathe. b. Vertical lathe #11 in the Machine Shop, guards were missing on the main power drive belts and pulleys on the back of the lathe. c. Horizontal lathe #40 in the Machine Shop, guards were missing on the oil pump drive belt and pulley on the back of the lathe. d. Spinner #9 in the Spinner Department, the guard was not installed properly over the main belt and pulley motor on the back side of the spinner.
Recent events (2)
- — I (S) $2500
- — Z (S) $4900
1910.219 E03 I
- Issued
- Apr 6, 2015
- Abate by
- May 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section. On or about October 08, 2014, and at times prior thereto, the employer did not ensure that belts and pulleys were guarded, exposing employees to the hazards of being caught in belt/pulley pinch points. a. Vertical lathe #41 in the Machine Shop, guards were missing on the main power drive belts and pulleys on the back of the lathe. b. Vertical lathe #11 in the Machine Shop, guards were missing on the main power drive belts and pulleys on the back of the lathe. c. Horizontal lathe #40 in the Machine Shop, guards were missing on the oil pump drive belt and pulley on the back of the lathe. d. Spinner #9 in the Spinner Department, the guard was not installed properly over the main belt and pulley motor on the back side of the spinner.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 F03
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $3,500 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven (7) feet or less above the floor or platform were not enclosed: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that sprockets and chains were enclosed, exposing employees to the hazard of being caught in the sprockets and chains. a. In the Saw Department on the #2 Saw, the sprocket and chain for the casting roller was not enclosed. b. In the End Plate Area on the #2 Mold Oven, the sprocket and chain for the over door was not enclosed.
Recent events (2)
- — I (S) $1500
- — Z (S) $3500
1910.242 A
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $3,500 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: On or about October 08, 2014, and at times prior thereto, multiple hammers found throughout the facility were used with cracked and broken handles, exposing employees to the hazards of being struck by the broken hammers.
Recent events (2)
- — I (S) $1500
- — Z (S) $3500
1910.242 B
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about October 08, 2014, air nozzles were routinely used for cleaning at pressures up to 55 psig, exposing employees to the hazards of being struck by chips and/ or high pressure air.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.243 C01
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)(a): On or about October 08, 2014, and at times prior thereto, in the shipping department the employer did not ensure that the abrasive wheel installed on the portable DeWalt Angle Grinder was provided with a safety guard, exposing employees to the hazards of being struck by flying debris in the event of wheel breakage.
Recent events (2)
- — I (S) $1000
- — Z (S) $2100
1910.253 B02 IV
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,100 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that the compressed oxygen tank in the Revert area was stored with a cap.
Recent events (2)
- — I (S) $1000
- — Z (S) $2100
1910.254 D09 III
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $3,500 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced: On or about October 08, 2014, and at times prior thereto, in the maintenance shop the employer did not ensure arc welding cables were free of damage to the insulation, exposing the employees to the hazards of heated conductors and electrical shock.
Recent events (2)
- — I (S) $1500
- — Z (S) $3500
1910.303 B02
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $3,500 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing and labeling. On or about October 08, 2014, and at times prior thereto, metal boxes with knockouts, designed to be mounted, were used as part of shop-built portable extension cords found throughout the facility, exposing employees to the hazards of electrical shock.
Recent events (2)
- — I (S) $1500
- — Z (S) $3500
1910.303 B07 IV
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $4,900 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(iv): There were damaged parts that adversely affected safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating: On or about October 08, 2014, and at times prior thereto, electrical equipment with damaged parts was not taken out of service or repaired, exposing employees to the hazard of electrical shock. a. In the spinner department, the 480 volt conduits running along the edge of spinners #10 and #11 were bent, broken and corroded. b. In the End Plate Department on mold oven #1, the power control box on/off switches were broken and recessed in the control box requiring that the employees put their fingers into the control box. c. In the End Plate Department on mold oven #2, the power control box on/off switches were broken and recessed in the control box requiring that the employees put their fingers into the control box. d. In the Metal Storage Area, the power control box on/off switches were broken for compressor #2 and recessed in the control box requiring that the employees put their fingers into the control box. e. In the Saw Department on Saw #1, the power control box on/off switches were broken and recessed in the control box requiring that the employees put their fingers into the control box. f. In the Saw Department on Saw #2, the power control box on/off switches were broken and recessed in the control box requiring that the employees put their fingers into the control box. g. In the Machine Shop on lathe #24, the power control handle was broken and missing. h. In the Machine Shop on lathe #40, the power control handle was broken and missing.
Recent events (2)
- — I (S) $2500
- — Z (S) $4900
1910.303 F02
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that each breaker in the breaker box located in the end plate department was marked to indicate its purpose.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 A02 X
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $3,500 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that flexible cords and cables were protected from accidental damage, exposing employees to the hazards electrical shock. a. In the Foundry Department next to furnace C & D, the floor fan's cord was run between a metal floor cover and the concrete floor exposing it to a pinch point. b. In the AmStock Area, the floor fan's cord was run under a pallet and metal guard frame that was cut and damaged in several areas along the cord. c. In the Shipping Department, the Dewalt circular saw's cord was cut and damaged in several areas along the cord. d. In the Machine Shop, the Black & Decker HD 6 inch Grinders cord was damaged in several areas along the cord and had been repaired with electrical tape. e. In the Heat Treat Department the job made cooler's cord was run through a hole in the wall exposing it to sharp edges of the sheet metal.
Recent events (2)
- — I (S) $1300
- — Z (S) $3500
1910.305 B01 I
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $2,800 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed. On or about October 08, 2014, and at times prior thereto, the employer did not ensure that the power supply conductor holes on the power control box for job made saw #3 were effectively closed, exposing employees to the hazards of electrical shock.
Recent events (2)
- — I (S) $1000
- — Z (S) $2800
1910.305 B01 II
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about October 08, 2014, the employer did not ensure that the unused openings in the following electrical boxes were effectively closed, exposing employees to the hazards of electrical shock. a. In the Foundry on Melt Deck G & H, the 110 Volt junction box was missing a knockout on the side of the box. b. In the CNC Department on the back side of the 220 volt Moriseiki LL-7 CNC Machine, two knockouts were not closed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 I
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that junction boxes were covered in the Heat Treat Department, exposing employees to the hazard of electrical shock. a. On mold oven #4, wiring for the 110 Volt junction box was missing covers in two areas. b. On mold oven # 2, the transformers were missing covers on both sides of the oven.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 D02
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $3,500 · Current $1,300 Reduced
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures approved for the purpose and were not dead front: On or about October 08, 2014, and at times prior thereto, the employer did not ensure that the panel board located next to the milling machine in the machine shop had a dead front cover installed, exposing employees to the hazards of electrical shock and burns.
Recent events (2)
- — I (S) $1300
- — Z (S) $3500
1910.305 G01 IV B
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: On or about October 08, 2014, and at times prior thereto, the employer used a 25 foot orange extension cord that ran through the ceiling to supply power to a security camera located on the roof, exposing employees to the hazards of fire.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G02 III
- Issued
- Apr 6, 2015
- Abate by
- Apr 13, 2015
- Penalty
- Initial $4,900 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that the strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws. On or about October 08, 2014, and at times, prior thereto, the employer did not ensure cords and cables were connected to devices so that strain relief was provided, exposing employees to the hazards of electrical shock: a. In the Saw Department, the TPI Industrial floor fan had the electrical power cord pulled from the fan casing. b. In the Revert Area, the industrial fan's power cord had the outer sheathing pulled from the power control box. c. In the CNC Department, on the #4 CNC Machine on the Chip Tote Conveyor's motor control, the outer sheathing of the wiring was pulled away from the motor. d. In the CNC Department, on the #3 CNC Machine on the Chip Tote Conveyor's motor control, the outer sheathing of the wiring was pulled away from the controls. e. In the CNC Department, on the #6 CNC Machine on the Chip Tote Conveyor's motor control, the outer sheathing of the wiring was pulled away from the controls.
Recent events (2)
- — I (S) $2500
- — Z (S) $4900
More inspections at American Spincast, INC.
View American Spincast, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331513)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339991119.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.