ATHENS, TX ·
OSHA Inspection: DALLAS MANUFACTURING COMPANY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DALLAS MANUFACTURING COMPANY, INC. in 300 ATHENS BRICK ROAD, ATHENS, TX 75751 (NAICS 314999). OSHA activity number 339991580.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DALLAS MANUFACTURING COMPANY, INC.
- Site address
- 300 ATHENS BRICK ROAD
- City
- ATHENS
- State
- TX
- ZIP
- 75751
- Mailing
- 300 ATHENS BRICK ROAD, ATHENS, TX 75751
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 314999
- Employees
- 300
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Mar 2, 2015
- Abate by
- Mar 26, 2015
- Penalty
- Initial $4,500 · Current $2,760 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: This violation was most recently observed on or about February 19, 2015 when at least one employee was exposed to a fall hazard of more than four feet above the ground level while cleaning the fiber out of blower machine #9.
Recent events (2)
- · I (S) $2760
- · Z (S) $4500
1910.95 C01
- Issued
- Mar 2, 2015
- Abate by
- Mar 26, 2015
- Penalty
- Initial $4,500 · Current $3,000 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent: This violation occurred on or about February 28, 2015 when the employer did not administer a hearing conservation program for employees exposed to noise that exceeded an 8-hour time-weighted average (TWA) of 85 dBA. a. A blower working on machine 1 was exposed to continuous noise levels at 67.59% of the permissible 8-hour TWA. The equivalent dBA level of 67.59% is approximately 87.1 dBA. Sampling was performed for 451 minutes during one shift. Zero exposure was assumed for the un-sampled period of 29 minutes; b. A fiber filler and packer working on machine 17 was exposed to continuous noise levels at 80.20% of the permissible 8-hour TWA. The equivalent dBA level of 80.20% is approximately 88.4 dBA. Sampling was performed for 468 minutes during one shift. Zero exposure was assumed for the un-sampled period of 12 minutes; c. A fiber filler and packer working on machine 19 was exposed to continuous noise levels at 89.84% of the permissible 8-hour TWA. The equivalent dBA level of 89.84% is approximately 89.2 dBA. Sampling was performed for 467 minutes during one shift. Zero exposure was assumed for the un-sampled period of 13 minutes; d. A fiber filler and packer working on machine 17 was exposed to continuous noise levels at 71.07% of the permissible 8-hour TWA. The equivalent dBA level of 71.07% is approximately 87.5 dBA. Sampling was performed for 464 minutes during one shift. Zero exposure was assumed for the un-sampled period of 16 minutes.
Recent events (2)
- · I (S) $3000
- · Z (S) $4500
1910.212 A03 II
- Issued
- Mar 2, 2015
- Abate by
- Mar 26, 2015
- Penalty
- Initial $5,400 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): This violation occurred on or about October 8, 2014 when employees using vacuum sealers were exposed to an unguarded point of operation on the following machines: a. ALine HD-60-VS, serial number 6840-1 vacuum sealer b. Aline HD-600S, serial number 240/3/60 vacuum sealer c. Aline HD-600S, serial number 7054-2 vacuum sealer
Recent events (2)
- · I (S) $0
- · Z (S) $5400
More inspections in this industry (NAICS 314999)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339991580.