Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: PROST BREWING COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PROST BREWING COMPANY in 2540 19TH ST, DENVER, CO 80211 (NAICS 312120). OSHA activity number 339993651.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Prost Brewing Company for free Get an email when a new federal OSHA severe-injury report for Prost Brewing Company is published. One employer, no account, unsubscribe in one click.
Site address
2540 19TH ST
City
DENVER
State
CO
ZIP
80211
Mailing
938 PTARMIGAN RUN, LOVELAND, CO 80538
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
312120
Employees
20
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 29, 2015
Abate by
Feb 24, 2015
Penalty
Initial $1,700 · Current $850 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were injured when the ceiling they were standing on collapsed causing them to come in contact with the concrete floor below.        (a)     Prost Brewing Company at 2540 19th St., Denver, CO 80211: On and before October 2, 2014, employees above the Brewing Area, standing on a steel storage rack at an elevation of approximately 10-15 feet above the floor, were not adequately protected from falls in that the anchor connectors used in the Personal Fall Arrest System were standard hardware store-bought eyebolts that were not rated or load tested to ensure they were capable of withstanding (without breaking) a 5,000-pound (22.2kN) load.
Recent events (2)
  • · I (S) $850
  • · Z (S) $1700

1910.23 A02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 29, 2015
Abate by
Feb 24, 2015
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1910.23(a)(2):  Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening:    (a)         Prost Brewing Company at 2540 19th St., Denver, CO 80211: On and before October 2, 2014, the employer did not ensure that a ladderway opening to the loft area was guarded by a swinging gate or so offset that a person could not walk directly into the opening. This condition exposed employees to a fall hazard of approximately 10 feet, 8 inches.
Recent events (2)
  • · I (S) $850
  • · Z (S) $1700

1910.178 M02

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 29, 2015
Abate by
Feb 24, 2015
Penalty
Initial $1,700 · Current $850 Reduced
29 CFR 1910.178(m)(2): Employee(s) stood under or passed under the elevated portion of a powered industrial truck(s):               (a)         Prost Brewing Company at 2540 19th St., Denver, CO 80211: On and before October 2, 2014, the employer did not ensure that employees were prevented from passing under a forklift suspended load such that employees routinely passed under the forklift load during the process of hanging a super sack of grain. This condition exposed employees to struck-by or crushing hazards..
Recent events (2)
  • · I (S) $850
  • · Z (S) $1700

1910.132 D02

Other-than-serious 1 instance 6 exposed
Issued
Jan 29, 2015
Abate by
Feb 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment had been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):    (a)   Prost Brewing Company at 2540 19th St., Denver, CO 80211: On and before October 2, 2014, the employer did not ensure through written verification that a workplace personal protective equipment (PPE) hazard assessment had been performed.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.303 G01 I

Other-than-serious 1 instance 6 exposed
Issued
Jan 29, 2015
Abate by
Feb 24, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(i):  Workspace was less than 3 feet in front of electric equipment operating at 600 volts nominal, or less:     (a)       Prost Brewing Company at 2540 19th St., Denver, CO 80211: On and before October 2, 2014, the employer did not maintain workspace of at least 3 feet in front of electrical panels located at the back wall of the brew room in that access to the panels was restricted with only 19 inches of clearance in front. This condition exposed employees to electrical and mechanical hazards.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339993651.