Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SCG COMMERCIAL REAL ESTATE LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCG COMMERCIAL REAL ESTATE LLC in 75 MAIN STREET, NORWALK, CT 06851 (NAICS 238290). OSHA activity number 339993800.

Watch SCG Commercial Real Estate LLC — free Get an email when a new federal OSHA severe-injury report for SCG Commercial Real Estate LLC is published. One employer, no account, unsubscribe in one click.
Site address
75 MAIN STREET
City
NORWALK
State
CT
ZIP
06851
Mailing
74 WEST PARK PLACE, STAMFORD, CT 06901
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
3
Ownership type
A

3 citations on file for this inspection.

1910.29 A03 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1960.00 Reduced
29 CFR 1910.29(a)(3)(i): The maximum work level height shall not exceed four (4) times the minimum or least base dimensions of any mobile ladder stand or scaffold. Where the basic mobile unit does not meet this requirement, suitable outrigger frames was not employed to achieve this least base dimension, nor were provisions made to guy or brace the unit against tipping.  JOBSITE:  The working height of the platform of the mobile scaffold, from which an employee was working at a height of 15 feet 6 inches was more than four (4) times the minimum or least base dimension of the scaffold, and appropriate and safe provisions were not utilized to prevent the unit from tipping.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.29 A03 VII

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1400.00 Reduced
29 CFR 1910.29(a)(3)(vii): Work levels 10 feet or higher above the ground or floor did not have  a guardrail of 2" x 4" nominal or the equivalent, installed no less than 36" or more than 42" high, with a mid-rail of 1"x 4" nominal lumber or equivalent:  JOBSITE:  The working platform of the mobile scaffold, from which an employee was to replace a bulb of a light fixture at a height of 15 feet 6 inches from the ground was not equipped with a standard guardrail system.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.29 A03 VI

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.29(a)(3)(vi): All scaffold work levels 10 feet or higher above the ground or floor were not equipped with a standard (4-inch nominal) toeboard.  JOBSITE:  The platform of the mobile scaffold, from which an employee was working at a height of 15 feet 6 inches from the ground was not equipped with toeboards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339993800.