ROCHELLE, IL —
OSHA Inspection: MASTER GRAPHICS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MASTER GRAPHICS LLC in 1100-A S. MAIN STREET, ROCHELLE, IL 61068 (NAICS 323110). OSHA activity number 339994170.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASTER GRAPHICS LLC
- Site address
- 1100-A S. MAIN STREET
- City
- ROCHELLE
- State
- IL
- ZIP
- 61068
- Mailing
- 1100-A S. MAIN STREET, ROCHELLE, IL 61068
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323110
- Employees
- 88
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.157 E03
- Issued
- Mar 27, 2015
- Penalty
- Initial $1,785 · Current $1,250 Reduced
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: Building #4 Warehouse- Portable fire extinguishers available for employee use had not received annual maintenance checks since 2006, exposing employees to fire hazards in the event of malfunctioning extinguishers. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (S) $1249.5
- — Z (S) $1785
1910.178 L01 I
- Issued
- Mar 27, 2015
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). Shipping & Receiving- The employer did not ensure that each powered industrial truck operator was competent to operate a powered industrial truck prior to driving a vehicle in the workplace, exposing employees to struck-by hazards. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.305 G02 III
- Issued
- Mar 27, 2015
- Penalty
- Initial $2,380 · Current $1,666 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Building #4 Warehouse- A flexible extension cord (110-120v) used to power the scale did not have a strain relief device and strain was being transmitted to the terminal screws. Employees were exposed to arcing and fire hazards. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (S) $1666
- — Z (S) $2380
1910.37 B02
- Issued
- Mar 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit must be clearly visible and marked by a sign reading "Exit." Building #4 Warehouse- The inside exit door leading to the outside South exit door was not marked as an exit, exposing employees to delayed egress and smoke inhalation in the event of a fire. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 B02
- Issued
- Mar 27, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling. Building #4, Shipping- A relocatable power tap (power strip), which was not designed for use in an industrial environment, was used to supply power to a stretch wrapper and scale, with an extension cord for the scale plugged into it, exposing employees to overloading and overheating of electrical components that could contribute to a fire. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Master Graphics LLC
View Master Graphics LLC's full OSHA safety record →
More inspections in this industry (NAICS 323110)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339994170.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.