Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CARUS CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of CARUS CORPORATION in 1500 EIGHTH STREET, LA SALLE, IL 61301 (NAICS 325188). OSHA activity number 339995185.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Carus Corporation for free Get an email when a new federal OSHA severe-injury report for Carus Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
CARUS CORPORATION
Site address
1500 EIGHTH STREET
City
LA SALLE
State
IL
ZIP
61301
Mailing
1500 EIGHTH STREET, LA SALLE, IL 61301
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
83
Ownership type
Private (A)

3 citations on file for this inspection.

1910.23 C01

Other-than-serious 1 instance 5 exposed
Issued
Feb 26, 2015
Abate by
Apr 2, 2015
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard when required per the standard.    Employees were required to remove a retractable fall protection barrier for material to be moved in and out of the second floor of the facility. Once the barrier was removed, employees were exposed to a 12 foot fall due to an unguarded open-sided floor.  The employer did not ensure every open-sided floor greater than 4 feet was adequately guarded at all times.        Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)
Recent events (3)
  • · F (O) $4900
  • · C (S) $4900
  • · Z (S) $4900

1910.1000 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 26, 2015
Abate by
Apr 2, 2015
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.1000(a)(1): Employee(s) were exposed to an airborne concentration of manganese listed in Table Z-1 in excess of the ceiling concentration of 5 milligrams per cubic meter:  On October 27, 2014, the chemical operator running the Wyssmont drier and siever was exposed to manganese at a ceiling concentration of 5.651 milligrams per cubic meter of air, approximately 1.13 times the ceiling concentration (C) of 5 milligrams per cubic meter of air; This limit has been established to prevent an increased risk of Parkinson-like symptoms, neuromuscular impairment, and manganese pneumonia. The sample was collected over a 13 minute sampling period, with an assumed exposure of zero for the remaining 2 minutes.   Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
  • · F (S) $0
  • · C (S) $3500
  • · Z (S) $3500

1910.1000 E

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Feb 26, 2015
Abate by
Apr 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  The employer did not install engineering controls that effectively reduced and maintained the exposure of the chemical operator to manganese while running the Wyssmont dryer and siever. On October 27, 2014, the chemical operator running the Wyssmont drier and siever was exposed to manganese at a ceiling concentration of 5.651 milligrams per cubic meter of air, approximately 1.13 times the ceiling concentration (C) of 5 milligrams per cubic meter of air; This limit has been established to prevent an increased risk of Parkinson-like symptoms, neuromuscular impairment, and manganese pneumonia. The sample was collected over a 13 minute sampling period, with an assumed exposure of zero for the remaining 2 minutes.   Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (3)
  • · F (S) $0
  • · C (S) $0
  • · Z (S) $0

View Carus Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339995185.