Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: L AND G CONSTRUCTION, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of L AND G CONSTRUCTION, LLC. in 4160 TRUEMAN BLVD, HILLIARD, OH 43026 (NAICS 238130). OSHA activity number 339995391.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch L and G Construction, LLC. for free Get an email when a new federal OSHA severe-injury report for L and G Construction, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
4160 TRUEMAN BLVD
City
HILLIARD
State
OH
ZIP
43026
Mailing
4924 BLUFFTON PARKWAY BUILDING 18 #302, BLUFFTON, SC 29910
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
22
Ownership type
Private (A)

2 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 1 exposed
Issued
Dec 4, 2014
Abate by
Jan 8, 2015
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1): Within ten calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section:  a.  The employer has failed to submit abatement certification within ten days of the abatement date, November 1, 2014, for a violation of 29 CFR 1926.501(b)(1), issued as citation 1, item 1, and described as follows:  On the second floor of the building an employee was leaning out of the framed walls to attach exterior sheeting, the employee's personal fall arrest system vertical lifeline was fully extended and tied around interior wall studs, thereby exposing him to a 12 foot fall hazard.
Recent events (1)
  • · Z (O) $400

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 14, 2014
Abate by
Nov 1, 2014
Penalty
Initial $2,040 · Current $2,040
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  a. On the second floor of the building an employee was leaning out of the framed walls to attach exterior sheeting, the employee's personal fall arrest system vertical lifeline was fully extended and tied around interior wall studs, thereby exposing him to a 12 foot fall hazard.
Recent events (1)
  • · Z (S) $2040

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 339995391.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.