Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: DON JULIAN'S REPAIR, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DON JULIAN'S REPAIR, INC. in 3161 MANTILLA DR (LOT 174), JACKSONVILLE, FL 32246 (NAICS 238130). OSHA activity number 339996753.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DON Julian'S Repair, INC. — free Get an email when a new federal OSHA severe-injury report for DON Julian'S Repair, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3161 MANTILLA DR (LOT 174)
City
JACKSONVILLE
State
FL
ZIP
32246
Mailing
1536 OAK LACE CT., JACKSONVILLE, FL 32225
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Oct 16, 2014
Penalty
Initial $2,100 · Current $1,365 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    a.  On or about October 4, 2014, at the south side of the building, one employee using a pneumatic air nail gun to install plywood on a residential roof was not wearing eye protection, exposing himself to being struck by flying debris or nails.
Recent events (2)
  • — I (S) $1365
  • — Z (S) $2100

1926.501 B13

Serious Gravity 10 5 instances 5 exposed
Issued
Oct 16, 2014
Penalty
Initial $4,900 · Current $3,185 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a.  On or about October 4, 2014, at the west side of the building, an employee installing fascia while standing on the leading edge top plate was not protected from a 22ft-7in fall hazard by the use of a fall protection system.     b.  On or about October 4, 2014, at the south side of the building, an employee doing framing work while standing on the leading edge top plate was not protected from a 22ft-7in fall hazard by the use of a fall protection system.    c.  On or about October 4, 2014, at the south side of the building, an employee doing sheathing work on a 4:12 pitch roof was not protected from an 11 feet fall hazard by the use of a fall protection system.    d.  On or about October 4, 2014, at the north side of the building, an employee doing sheathing work on a 4:12 pitch roof was not protected from a 10 feet fall hazard by the use of a fall protection system.    e.  On or about October 4, 2014, at the north side of the building, an employee doing framing work while standing on the leading edge top plate was not protected from a 20 feet fall hazard by the use of a fall protection system.
Recent events (2)
  • — I (S) $3185
  • — Z (S) $4900

View DON Julian'S Repair, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339996753.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.