Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MPH, INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of MPH, INC in 6350 N. LUCERNE, KANSAS CITY, MO 64151 (NAICS 722513). OSHA activity number 339999047.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch MPH, INC — free Get an email when a new federal OSHA severe-injury report for MPH, INC is published. One employer, no account, unsubscribe in one click.
Establishment
MPH, INC
Site address
6350 N. LUCERNE
City
KANSAS CITY
State
MO
ZIP
64151
Mailing
6350 N. LUCERNE, KANSAS CITY, MO 64151
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722513
Employees
20
Ownership type
A

1 citation on file for this inspection.

1910.303 B06

Serious Gravity 10 1 instance 20 exposed
Issued
Nov 19, 2014
Abate by
Dec 2, 2014
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.303(b)(6):  Deteriorating agents. Unless identified for use in the operating environment, no conductors or equipment shall be located in damp or wet locations; where exposed to gases, fumes, vapors, liquids, or other agents that have a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures:  (A)  On October 09, 2014, in the cooking and prep areas of the facility, employees were exposed to serious electrical related injuries, in that the outer jacket of the flexible power cord to the cooking timer unit had been damaged and compromised due to the deteriorating effect of the extreme heat temperatures of the surrounding cooking area. As a result, in April-May 2014, one employee received an electrical shock while placing a metal frying basket onto an energized metal shelf unit where the defective electrical cord has been affixed to. The employee was taken to a local area medical facility for treatment.    Abatement certification is required for this item; use the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET for this purpose.
Recent events (1)
  • — Z (S) $7000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 339999047.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.