Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DELFINO AGUADO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DELFINO AGUADO in 745 ADAMS DR., WEATHERFORD, TX 76087 (NAICS 238140). OSHA activity number 339999054.

Watch Delfino Aguado — free Get an email when a new federal OSHA severe-injury report for Delfino Aguado is published. One employer, no account, unsubscribe in one click.
Establishment
DELFINO AGUADO
Site address
745 ADAMS DR.
City
WEATHERFORD
State
TX
ZIP
76087
Mailing
904 TREE DR., GRANBURY, TX 76048
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.451 C02

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1400.00 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:    On or about October 9, 2014, employees performing masonry activities on a commercial building were working on a tubular welded scaffold system that did not have mud sills or base plates installed on the poles/legs.  Employees were exposed to the hazards of a scaffold collapse and fall.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 C03

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement.  On or about October 9, 2014, employees performing masonry activities on a commercial building were working on a scaffold system that was not adequately braced exposing employees to the hazards of a fall and struck-by due to scaffold collapse.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.  On or about October 9, 2014, the employer did not ensure that a ladder was provided to access or egress the scaffold exposing employees to fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A01

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area.  On or about October 9, 2014, employees working on a scaffold system without receiving training in hazard recognition for scaffolds were exposed to multiple fall hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0