Referral inspection · Health discipline

On , OSHA opened a referral health inspection of VSE CORPORATION in BLDG. 430256 AREA 43, CAMP PENDLETON, CA 92055 (NAICS 811310). OSHA activity number 340002799.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VSE Corporation — free Get an email when a new federal OSHA severe-injury report for VSE Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
VSE CORPORATION
Site address
BLDG. 430256 AREA 43
City
CAMP PENDLETON
State
CA
ZIP
92055
Mailing
6348 WALKER LANE, ALEXANDRIA, VA 22310
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
17
Ownership type
A

8 citations on file for this inspection.

1910.132 D01

Other-than-serious 1 instance 17 exposed
Issued
Apr 3, 2015
Abate by
Jul 11, 2015
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    At the establishment - On or about 10/10/2014, and at times prior thereto, the employer did not assess the workplace to determine if chemicals of use, including but not limited to isocyanate paints, require skin protection exposing employees to the hazards associated with dermatitis and chemical skin absorption.
Recent events (3)
  • — F (O) $3500
  • — C (S) $5000
  • — Z (S) $5000

1910.134 D01 I

Other-than-serious 1 instance 17 exposed
Issued
Apr 3, 2015
Abate by
Jul 11, 2015
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.134(d)(1)(i): Selection of appropriate respirators was not based on the respiratory hazard(s) to which the worker was exposed and user factors that affect respirator performance and reliability:    At the establishment - On or about 10/10/2014, and at times prior thereto, employees were required to use 3M Model 8293 P100 filtering facepiece respirators while applying chemicals, including but not limited to, T-32 rust cop and CARC paints, exposing employees to respiratory hazards associated with airborne isocyanate and organic chemical vapors.
Recent events (3)
  • — F (O) $3500
  • — C (S) $5000
  • — Z (S) $5000

1910.134 D01 III

Other-than-serious 1 instance 17 exposed
Issued
Apr 3, 2015
Abate by
Jul 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:    At the establishment - On or about 10/10/2014, and at times prior thereto, the employer did not identify and evaluate chemical vapor hazards in the workplace while employees were applying chemicals, including but not limited to, T-32 rust cop and CARC paints, exposing employees to respiratory hazards associated with airborne isocyanate and organic chemical vapors.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 10 1 instance 17 exposed
Issued
Apr 3, 2015
Abate by
Jul 11, 2015
Penalty
Initial $7,000 · Current $4,900 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    At the establishment - On or about 10/10/2014, and at times prior thereto, the employer did not ensure that employees who were required to wear negative pressure 3M Model 8293 P100 filtering facepiece respirators while grinding parts and applying paint, including but not limited to, T-32 rust cop and CARC paints, were medically evaluated exposing the worker to the hazards associated with respiratory and cardiovascular distress.
Recent events (3)
  • — F (S) $4900
  • — C (S) $7000
  • — Z (S) $7000

1910.134 F01

Serious Gravity 5 1 instance 17 exposed
Issued
Apr 3, 2015
Abate by
Apr 29, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  At the establishment - On or about 10/10/2014, and at times prior thereto, the employer did not ensure that employees who were required to wear negative pressure 3M Model 8293 P100 filtering facepiece respirators while grinding parts and applying paint, including but not limited to, T-32 rust cop and CARC paints, were fit tested exposing the worker to the hazards associated metal oxide dusts, isocyanate and other chemical vapors. 29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  At the establishment - On or about 10/10/2014, and at times prior thereto, the employer did not ensure that employees who were required to wear negative pressure 3M Model 8293 P100 filtering facepiece respirators while grinding parts and applying paint, including but not limited to, T-32 rust cop and CARC paints, were fit tested exposing the worker to the hazards associated metal oxide dusts, isocyanate and other chemical vapors.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.304 G05

Other-than-serious 1 instance 17 exposed
Issued
Apr 3, 2015
Abate by
Jul 11, 2015
Penalty
Initial $4,250 · Current $2,975 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    Bldg. 430256 outdoor area, Shop Vac - On or about 10/10/2014, and at times prior thereto, employees were exposed to electrical shock hazards in that the vacuum's grounding pin was missing.
Recent events (3)
  • — F (O) $2975
  • — C (S) $4250
  • — Z (S) $4250

1904.39 A

Other-than-serious 1 instance 17 exposed
Issued
Apr 3, 2015
Abate by
Jul 11, 2015
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1904.39(a): The employer did not orally report the death of an employee within eight hours after the death of the employee:    Camp Pendleton, Bldg. 430256 outdoor area - On or about 10/10/2014, the employer failed to report the death of an employee to OSHA within eight hours.
Recent events (3)
  • — F (O) $3500
  • — C (O) $5000
  • — Z (O) $5000

1910.1200 F05 I

Other-than-serious 1 instance 17 exposed
Issued
Apr 3, 2015
Abate by
Jul 11, 2015
Penalty
Initial $5,000 · Current $3,500 Reduced
29 CFR 1910.1200(f)(5)(i): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the identity of the hazardous chemical(s) contained therein:    Bldg. 430256 outdoor area, storage cart - On or about 10/10/2014, a container with pneumatic oil was not labeled with its chemical identification.
Recent events (3)
  • — F (O) $3500
  • — C (O) $5000
  • — Z (O) $5000