OSHA Inspection: WAGNER EQUIPMENT CO.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WAGNER EQUIPMENT CO. in 18000 SMITH ROAD, AURORA, CO 80011 (NAICS 333132). OSHA activity number 340006840.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wagner Equipment CO. — free Get an email when a new federal OSHA severe-injury report for Wagner Equipment CO. is published. One employer, no account, unsubscribe in one click.
Site address
18000 SMITH ROAD
City
AURORA
State
CO
ZIP
80011
Mailing
18000 SMITH ROAD, AURORA, CO 80011
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333132
Employees
1586
Ownership type
A

6 citations on file for this inspection.

1910.106 E02 III

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 23, 2015
Abate by
Apr 5, 2015
Penalty
Initial $2,550 · Current $2,040 Reduced
29 CFR 1910.106(e)(2)(iii): Areas in which flammable liquids are transferred from one tank or container to another container shall be separated from other operations in the building by adequate distance or by construction having adequate fire resistance. Drainage or other means shall be provided to control spills. Adequate natural or mechanical ventilation shall be provided.   a)    Wagner Equipment Co. at 18000 Smith Road, Aurora, CO 80011: On and before 10/7/14, the employer did not ensure that flammable liquids in the machine shop area were transferred from one container to another container was separated from other operations in the building. The transfer was being conducted next to the mechanical work of an RV, no drainage or secondary containment was provided to control spills. This condition exposed employees to a fire hazard.           Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2040
  • — Z (S) $2550

1910.106 E06 I

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 23, 2015
Abate by
Apr 5, 2015
Penalty
Initial $4,250 · Current $3,400 Reduced
29 CFR 1910.106(e)(6)(i): Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.       a)    Wagner Equipment Co. at 18000 Smith Road, Aurora, CO 80011: On and before 10/7/14, the employer did not ensure that adequate precaution was taken to prevent the ignition of flammable vapors in the wash bay area. This condition exposed employees to a fire hazard which resulted in two employees being injured with 2nd and 3rd degree burns.             Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $3400
  • — Z (S) $4250

1910.106 E06 II

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 23, 2015
Abate by
Apr 5, 2015
Penalty
Initial $3,400 · Current $2,720 Reduced
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.       a)    Wagner Equipment Co. at 18000 Smith Road, Aurora, CO 80011: On and before 10/7/14, the employer did not ensure that flammable liquids in the machine shop area were dispensed into containers unless the nozzle and container are electrically grounded. The 4 black 55 gallon drums were not electrically bonded and grounded while transferring flammable liquids. This condition exposed employees to a fire hazard.             Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2720
  • — Z (S) $3400

1910.106 E09 II

Serious Gravity 1 1 instance 5 exposed
Issued
Mar 23, 2015
Abate by
Apr 5, 2015
Penalty
Initial $2,550 · Current $2,040 Reduced
29 CFR 1910.106(e)(9)(ii): Adequate aisles shall be maintained for unobstructed movement of personnel and so that fire protection equipment can be brought to bear on any part of flammable liquid storage, use, or any unit physical operation.  a)    Wagner Equipment Co. at 18000 Smith Road, Aurora, CO 80011: On and before 10/7/14, the employer did not ensure that flammable liquids stored in the machine shop area had adequate aisles free from obstruction of personnel and so that fire protection can be brought in. The flammable storage area was blocked by 2 RVs in the shop.  This condition exposed employees to a fire hazard.         Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $2040
  • — Z (S) $2550

1910.1200 F06 II

Deleted Serious Gravity 1 1 instance 5 exposed
Issued
Mar 23, 2015
Abate by
Apr 10, 2015
Penalty
Initial $2,550 · Current $0 Reduced
29 CFR 1910.1200(f)(6)(ii): Product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals, and which, in conjunction with the other information immediately available to employees under the hazard communication program, will provide employees with the specific information regarding the physical and health hazards of the hazardous chemical.      a)              Wagner Equipment Co. at 18000 Smith Road, Aurora, CO 80011: On and before 10/7/14, the employer did not ensure that each 55 gallon drum of hazardous chemicals in the workplace was properly identified. Parts wash solvent and brake parts solvent was transferred into smaller containers and were not labeled and similar black 55 gallon drums had handwritten names on the tops of the drum. This condition exposed employees to a chemical hazard.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $2550

1910.1200 H01

Other-than-serious 1 instance 5 exposed
Issued
Mar 23, 2015
Abate by
Apr 10, 2015
Penalty
Initial $3,400 · Current $2,720 Reduced
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.    a)              Wagner Equipment Co. at 18000 Smith Road, Aurora, CO 80011: On and before 10/7/14, the employer did not ensure that employees were effectively informed and trained on new chemical hazards that was introduced into their work area. The employer had recently purchased a 55 gallon drum of Focus Dash, a brake parts wash for the shop and did not train their employees. This condition exposed employees to a chemical and fire hazard.        Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (O) $2720
  • — Z (S) $3400

View Wagner Equipment CO.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340006840.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.