Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ORANGE COUNTY IRONWORKS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ORANGE COUNTY IRONWORKS, LLC in 36 MAYBROOK RD., MONTGOMERY, NY 12549 (NAICS 238120). OSHA activity number 340007681.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Orange County Ironworks, LLC — free Get an email when a new federal OSHA severe-injury report for Orange County Ironworks, LLC is published. One employer, no account, unsubscribe in one click.
Site address
36 MAYBROOK RD.
City
MONTGOMERY
State
NY
ZIP
12549
Mailing
36 MAYBROOK RD., MONTGOMERY, NY 12549
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
52
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 30, 2014
Abate by
Jan 20, 2015
Penalty
Initial $4,900 · Current $3,281 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:     a) Establishment -  On or about 10/14/2014, the employer did not establish or utilize methods for isolating energy sources to disable machines and equipment, such as but not limited to the CNC Machines, band saws and drills, to prevent unexpected release of energy, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $3281.25
  • — Z (S) $4900

1910.178 L01 I

Serious Gravity 5 2 instances 4 exposed
Issued
Dec 30, 2014
Abate by
Jan 12, 2015
Penalty
Initial $3,500 · Current $3,281 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a) Establishment, On or about 10/14/2014; The employer did not ensure operators of powered industrial trucks were competent to operate them safely, as demonstrated by the successful completion of the training and evaluation of operator performance.
Recent events (2)
  • — I (S) $3281.25
  • — Z (S) $3500

1910.178 Q07

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 30, 2014
Abate by
Jan 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service:  a) Establishment, On or about 10/14/2014; The employer did not ensure fork trucks were inspected to ensure safe operation prior to use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.243 C03

Serious Gravity 10 32 instances 14 exposed
Issued
Dec 30, 2014
Abate by
Jan 12, 2015
Penalty
Initial $4,900 · Current $3,281 Reduced
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinders (right angle head grinders) were not provided with safety guards having a maximum exposure angle of 180 degrees and located between the operator and wheel:    a) Fit-Up Area, On or about 10/14/2014, 14 employees using 32 portable grinders that were not guarded, exposing employees to flying metal chips, sparks, and broken wheel fragments.
Recent events (2)
  • — I (S) $3281.25
  • — Z (S) $4900

1910.303 B02

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 30, 2014
Abate by
Jan 12, 2015
Penalty
Initial $2,100 · Current $3,281
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Under the stand-up desk, South East corner; on or about 10/14/2014, there was a Relocatable Power Tap (Power strip) plugged into another. The daisy-chaining of these power strips are not used in accordance with listing or labeling. This potential overloaded circuit can expose employees to shock and fire hazards.
Recent events (2)
  • — I (S) $3281.25
  • — Z (S) $2100

1910.305 G01 IV A

Serious Gravity 1 2 instances 4 exposed
Issued
Dec 30, 2014
Abate by
Jan 12, 2015
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a) Outlet MBBI-2 - On or about 10/14/2014,  an extension cord was plugged into an outlet, ran along the floor, for a work light in the machine area exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

View Orange County Ironworks, LLC's full OSHA safety record →