Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORTLAND PRODUCE CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CORTLAND PRODUCE CO., INC. in 150 JOHNSON ROAD, FREEVILLE, NY 13068 (NAICS 424410). OSHA activity number 340010305.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cortland Produce CO., INC. — free Get an email when a new federal OSHA severe-injury report for Cortland Produce CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
150 JOHNSON ROAD
City
FREEVILLE
State
NY
ZIP
13068
Mailing
P. O. BOX 318, FREEVILLE, NY 13068
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424410
Employees
22
Ownership type
A

4 citations on file for this inspection.

1910.36 D01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Nov 3, 2014
Abate by
Nov 13, 2014
Penalty
Initial $1,600 · Current $0 Reduced
29 CFR 1910.36(d)(1):   Exit door was locked.  Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a)  Dry Storage, A Section, on or about 10/16/14:  The exit door was locked.  Abatement certification must be submitted for this item.  29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times:    a)  Dry Storage, A Section, on or about10/16/14:  Emergency lighting over the exit door was not functioning.    Abatement certification must be submitted for this item.
Recent events (3)
  • — J (S) $960
  • — C (S) $1600
  • — Z (S) $1600

1910.304 F01 IV

Other-than-serious 1 instance 3 exposed
Issued
Nov 3, 2014
Abate by
Nov 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.304(f)(1)(iv): Overcurrent devices for circuits rated 600 volts, nominal, or less, were not readily accessible to each employee or authorized building management personnel:  a)  Utility Room, on or about 10/16/14:  Circuit breaker panels were blocked by equipment, a ladder, boxes, etc.  Abatement certification must be submitted for this item.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Nov 3, 2014
Abate by
Nov 13, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a)  B Dock, on or about 10/16/14:  An orange extension cord providing current to a Frigidaire freezer was being used as permanent wiring.  Abatement certification must be submitted for this item.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 15 exposed
Issued
Nov 3, 2014
Abate by
Dec 6, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met; specifically:      1)  Labeling and other forms of warning;     2)  SDS requirements for the hazardous materials known to be present at the worksite;     3)  Employee training and information.  The written program must also include:      a) A complete list of hazardous chemicals known to be in the workplace;     b) Methods to inform employees of the hazards on non-routine tasks; and     c) Methods to inform other employer(s) of safety data sheet availability; the labeling system; and any precautionary measures to protect employees.   a)  At the establishment, on or about 10/16/14:  There was no written hazard communication program nor training for employees using and/or exposed to various products, including, but not limited to DEF Diesel exhaust fluid, engine oil, washer fluid, stainless steel cleaner, penetrating oil, etc.  Abatement certification must be submitted for this item.
Recent events (3)
  • — J (O) $0
  • — C (O) $0
  • — Z (O) $0

View Cortland Produce CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340010305.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.