Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HARVEY INDUSTRIES INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HARVEY INDUSTRIES INC. in 30 JACK'S BRIDGE ROAD, LONDONDERRY, NH 03053 (NAICS 326199). OSHA activity number 340010412.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Harvey Industries INC. — free Get an email when a new federal OSHA severe-injury report for Harvey Industries INC. is published. One employer, no account, unsubscribe in one click.
Site address
30 JACK'S BRIDGE ROAD
City
LONDONDERRY
State
NH
ZIP
03053
Mailing
30 JACK'S BRIDGE ROAD, LONDONDERRY, NH 03053
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
1500
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 6 exposed
Issued
Nov 5, 2014
Penalty
Initial $5,500 · Current $5,500
29 CFR 1910.212(a)(1): One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  (A) Thermo-True Dept. - The Makita Router bit was unguarded.   (B) Storm Door Dept. - The metal Brake had inadequate guarding.  (c) Designer Shape Dept. - The drill presses were unguarded.
Recent events (2)
  • — I (S) $5500
  • — Z (S) $5500

1910.145 C03

Other-than-serious 4 instances 425 exposed
Issued
Nov 5, 2014
Abate by
Nov 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(3): Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s):  (a) Production Shop - Electrical panels and switch gear were not labeled for electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Harvey Industries INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340010412.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.