OSHA Inspection: GONZALO ISIDIRO-ENCARNACION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GONZALO ISIDIRO-ENCARNACION in 1230 WELLINGTON PLACE, ALPHARETTA, GA 30009 (NAICS 238160). OSHA activity number 340011238.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gonzalo Isidiro-Encarnacion for free Get an email when a new federal OSHA severe-injury report for Gonzalo Isidiro-Encarnacion is published. One employer, no account, unsubscribe in one click.
Site address
1230 WELLINGTON PLACE
City
ALPHARETTA
State
GA
ZIP
30009
Mailing
3510 BUFORD HIGHWAY, APT. H-9, ATLANTA, GA 30329
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 4, 2014
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     (a) Roof, new residential construction located at 1230 Wellington Place, Alpharetta, GA 30009: Employee was exposed to falls while engaged in residential roofing activities on a 8/12 pitched roof at eave heights of approximately 21-feet, 6-inches from the lower level with no fall protection system in place.
Recent events (3)
  • · A (S) $2800
  • · I (S) $1680
  • · Z (S) $2800

1926.502 D17

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body belt was not located in the center of the wearer's back. The attachment point of the body narness was not located in the center of the wearer's back near shoulder level, or above the wearer's head.  (a) Roof, new residential construction located at 1230 Wellington Place, Alpharetta, GA 30009: Employee using a positioning belt as a fall protection system on an 11/12 pitched roof at eave heights of approximately 16-feet was not protected from fall hazards as an inadequate fall protection system was used. The attachment to the life-line was not made at the wearer's back on the D-Ring. A positioning device can not be used as a personal fall arrest system.