Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CARR & SONS MASONRY, INC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of CARR & SONS MASONRY, INC in 5127 BLOOMINGDALE AVE, TAMPA, FL 33619 (NAICS 238140). OSHA activity number 340012905.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Carr & Sons Masonry, INC — free Get an email when a new federal OSHA severe-injury report for Carr & Sons Masonry, INC is published. One employer, no account, unsubscribe in one click.
Site address
5127 BLOOMINGDALE AVE
City
TAMPA
State
FL
ZIP
33619
Mailing
3750 70TH AVENUE NORTH SUITE A, PINELLAS PARK, FL 33781
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
35
Ownership type
A

2 citations on file for this inspection.

1926.404 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Oct 30, 2014
Penalty
Initial $4,900 · Current $2,940 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection.    a) For employees working at 5127 Bloomingdale Avenue in Tampa, as observed on or about October 15, 2014. Employees were using electrical power supplied by the permanent wiring of the building that was not protected with the use of a ground fault circuit interrupter.
Recent events (2)
  • — I (O) $2940
  • — Z (S) $4900

1926.404 F06

Other-than-serious 1 instance 1 exposed
Issued
Oct 30, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) For employees working at 5127 Bloomingdale Avenue in Tampa, as observed on or about October 15, 2014. Employees were using an extension cord to supple power to a submersible sump pump that was missing the path to ground. Employees were working in a wet location.