FORT SCOTT, KS —
OSHA Inspection: NIECE PRODUCTS OF KANSAS INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NIECE PRODUCTS OF KANSAS INC in 3904 LIBERTY BELL RD., FORT SCOTT, KS 66701 (NAICS 332420). OSHA activity number 340013119.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NIECE PRODUCTS OF KANSAS INC
- Site address
- 3904 LIBERTY BELL RD.
- City
- FORT SCOTT
- State
- KS
- ZIP
- 66701
- Mailing
- 3904 LIBERTY BELL RD, FORT SCOTT, KS 66701
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 42
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.107 C02
- Issued
- Mar 6, 2015
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.107(c)(2): An open flame or spark producing equipment was present in the spraying area or within 20 feet thereof and not separated by a partition. In the paint booth, a paint shaker was being used to shake paint cans, exposing employees to an explosion hazard.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.107 C06
- Issued
- Mar 6, 2015
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.107(c)(6): Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined were not explosion-proof type approved for Class I, group D locations and did not otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations: In the paint booth, equipment did not meet the requirements of Class I, Division 1, Hazardous Locations, exposing employees to explosion hazards in the following instances: 1) The "Exit" sign mounted on the inside, South Wall, of the paint booth was not Class I, Division 1. 2) Class I, Division 1 equipment, such as the vapor proof light fixtures and conduit were not being maintained in that the fixtures were missing their vapor proof cover and the conduit was broken.
Recent events (2)
- — I (S) $2450
- — Z (S) $4900
1910.107 G07
- Issued
- Mar 6, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.107(g)(7): "NO SMOKING" sign(s) in large letters on contrasting color backgrounds were not conspicuously posted at spraying area(s) and paint storage room(s): On the exterior of the Paint Booth building, the facility was improperly marked regarding smoking, exposing employees to potential explosion and fire hazards in the following instances: 1) On the south side of the building, a "No Smoking" sign was not posted on the outside of the building. 2) The "No Smoking" signs on the north and east side of the building are inadequate in that the signs are faded an no longer conspicuous and no longer have a contrasting color background.
Recent events (2)
- — I (S) $0
- — Z (S) $2100
1910.180 D04
- Issued
- Mar 6, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.180(d)(4): Complete inspection(s) of crane(s) were not performed at intervals as generally defined in 1910.180(d)(ii) with a determination made as to whether deficiencies constituted a safety hazard: In the yard, the Grove Truck Mounted Crane had not received a periodic inspection, exposing employees to a potential struck by hazard.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
1910.180 D06
- Issued
- Mar 6, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.180(d)(6): Monthly, dated and signed inspection records and reports for truck crane(s) were not provided for critical items such as (but not limited to) brakes, crane hooks and ropes: In the yard, the Mobile Grove Crane had no certification record of a monthly periodic inspection, exposing employees to a potential struck by hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Mar 6, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): In the utility room in the Paint Booth, the exhaust fan belt and pulley was inadequately guarded in that the metal mesh had approximately 1 inch by 2 1/4 inch wide openings approximately 1 inch from the 3/8 inch wide belt, exposing employees to a caught in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.219 E01 I
- Issued
- Mar 6, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt: In the utility room in the Paint Booth, the exhaust fan belt and pulley was inadequately guarded in that the metal mesh had approximately 1 inch by 2 1/4 inch wide openings approximately 1 inch from the 3/8 inch wide belt, exposing employees to a caught in hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 II
- Issued
- Mar 6, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: In the utility room, electrical equipment had openings to live electrical equipment, exposing employees to electrical shock hazards in the following instances: 1) The air compressor electrical service disconnect box had three openings. 2) The air compressor power box had one opening on the top.
Recent events (2)
- — I (O) $1050
- — Z (S) $2100
1910.334 A02 I
- Issued
- Mar 6, 2015
- Abate by
- Mar 30, 2015
- Penalty
- Initial $2,100 · Current $1,050 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket): In the paint booth, cord and cord connected equipment had deficiencies that were creating explosion hazards in the following instances: 1) The paint shaker had cord sheathing fraying where it entered the shaker. 2) An extension cord used to power the paint shaker had a broken ground prong.
Recent events (2)
- — I (S) $1050
- — Z (S) $2100
More inspections at Niece Products of Kansas INC
View Niece Products of Kansas INC's full OSHA safety record →
More inspections in this industry (NAICS 332420)
More inspections in KS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340013119.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.