Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-02

OSHA Inspection: ADDISON FABRICATORS, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ADDISON FABRICATORS, INC in 30751 HIGHWAY 278 PO BOX 330, ADDISON, AL 35540 (NAICS 332410). OSHA activity number 340013143.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Addison Fabricators, INC for free Get an email when a new federal OSHA severe-injury report for Addison Fabricators, INC is published. One employer, no account, unsubscribe in one click.
Site address
30751 HIGHWAY 278 PO BOX 330
City
ADDISON
State
AL
ZIP
35540
Mailing
30751 HIGHWAY 278 PO BOX 330, ADDISON, AL 35540
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332410
Employees
37
Ownership type
A

10 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2014
Abate by
Jan 12, 2015
Penalty
Initial $2,975 · Current $1,785 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) On or about 10/16/2014 - Main Plant, the employer had not developed written procedures specifically for the equipment being utilized in the plant, such as but not limited to, lathes, press brake, shear, rollers and benders.
Recent events (2)
  • · I (S) $1785
  • · Z (S) $2975

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2014
Abate by
Jan 5, 2015
Penalty
Initial $3,570 · Current $2,142 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a)  On or about 10/16/2014 - Main Plant, the chuck on the Monarch horizontal lathe was not guarded.  (b)  On or about 10/16/2016 - Main Plant, the chuck on the J.J. McCabe vertical lathe was not guarded.
Recent events (2)
  • · I (S) $2142
  • · Z (S) $3570

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2014
Penalty
Initial $3,570 · Current $2,142 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:  (a) On or about 10/16/2014 - Main plant, the Baldor pedestal grinder was not adjusted properly.  The right side was adjusted to 1 1/2 inches and the left side was adjusted to 1 inch.
Recent events (2)
  • · I (S) $2142
  • · Z (S) $3570

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a)  On or about 10/16/2014 - Main Plant, the Baldor grinder tongue guards on the pedestal-mounted abrasive grinder (S10-237-2) were not adjusted to at least one-fourth inch. The right side was adjusted to 1 inch and the left side was adjusted to 1 inch.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.215(d)(3): The contact surface(s) of wheel(s), blotter(s) or flange(s) on grinding machine(s) were not flat and free or foreign matter:  (a)  On or about 10/16/2014 - Main plant, the Baldor Grinder contact surface(s) had several deep groves that weakened the stone's integrity.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2014
Abate by
Dec 26, 2014
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):   (a)  On or about 10/16/2014 - Main Plant, the J. J. McCabe Vertical Lathe pulley was not guarded.
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 15, 2014
Abate by
Dec 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  (a) On or about 10/16/2014 - Main Plant, the belt on the J.J. McCabe vertical lathe was not guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 15, 2014
Abate by
Dec 23, 2014
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a)  On or about 10/16/2014 - Main plant, the 240 volt panel at station 10 was blocked.
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.37 B02

Other-than-serious 1 instance 1 exposed
Issued
Dec 15, 2014
Abate by
Dec 26, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a)  On or about 10/16/2014 - Main Plant, the four exit doors were not marked with a sign.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.305 B01 II

Other-than-serious 1 instance 1 exposed
Issued
Dec 15, 2014
Abate by
Dec 23, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  (a)  On or about 10/16/2014 - Main Plant, electrical panels located at STA 8, 10, and by the McGabe lathe had openings that were not covered. The openings measured from 1/2-inch in diameter to 2 inches in diameter.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Addison Fabricators, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340013143.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.