OSHA Inspection: DCS SPECIALTY PACKAGING INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of DCS SPECIALTY PACKAGING INC. in 9700 LOONEY ROAD, PIQUA, OH 45356 (NAICS 561910). OSHA activity number 340017771.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch DCS Specialty Packaging INC. for free Get an email when a new federal OSHA severe-injury report for DCS Specialty Packaging INC. is published. One employer, no account, unsubscribe in one click.
Site address
9700 LOONEY ROAD
City
PIQUA
State
OH
ZIP
45356
Mailing
9700 LOONEY ROAD, PIQUA, OH 45356
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561910
Employees
13
Ownership type
Private (A)

4 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 21, 2014
Abate by
Jan 12, 2015
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.    The company had not developed nor implemented a energy control program consisting of energy control procedures, authorized and affected training and periodic inspections for two sheeter machines with electrical and pneumatic energy sources, two bandsaws, paper shear (cutter) and radial arm saw machine with only an electrical energy source.
Recent events (2)
  • · I (S) $1500
  • · Z (S) $2000

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 21, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes.    In the Production Area, on Sheeter Machine A, an operator was exposed to the pinch point hazard on three, 1/2 inch pulley belts to a 5 hp motor that was replaced and the guard was removed but not reinstalled.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.219 F01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 21, 2014
Abate by
Dec 11, 2014
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.219(f)(1): Gears. Gears shall be guarded in accordance with one of the following methods:    In the Production Area, on Sheeter Machine B, an operator was exposed to a pinch point hazard from the two tooth metal gears located on the side of the machine where the operator stands to feed the paper in the tension roller during set up and during machine operation.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $2000

1910.305 G01 IV A

Other-than-serious 1 instance 1 exposed
Issued
Nov 21, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure;  In the Production Area, on Sheeter Machine A, a 110 Volt AC  extension cord set was being used and a substitute for fixed wiring for power to a paper counter machine which did not move because it was a part of the operation of the Sheeter machine.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340017771.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.