ESSEX, MA —
OSHA Inspection: DEAN W. RICHARDS CUSTOM WOODWORKING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DEAN W. RICHARDS CUSTOM WOODWORKING, INC. in 17 WINTHROP STREET, ESSEX, MA 01929 (NAICS 321999). OSHA activity number 340019678.
Where did this inspection happen?
- Establishment
- DEAN W. RICHARDS CUSTOM WOODWORKING, INC.
- Site address
- 17 WINTHROP STREET
- City
- ESSEX
- State
- MA
- ZIP
- 01929
- Mailing
- 17 WINTHROP STREET, ESSEX, MA 01929
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321999
- Employees
- 3
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.107 B01
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.107(b)(1): Construction. Spray booths was not substantially constructed of steel, securely and rigidly supported, or of concrete or masonry except that aluminum or other substantial noncombustible material may be used for intermittent or low volume spraying. Spray booths shall be designed to sweep air currents toward the exhaust outlet. (a) Location - Spray Booth: On or about 10/16/14, the employer failed to provide a spray booth that was substantially constructed of steel.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.107 B05 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers: (a) Location - Spray Booth: On or about 10/16/14, the employer failed to provide automatic sprinklers on the downstream and upstream sides of the filters.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 C08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(c)(8): Portable lamps. Portable electric lamps shall not be used in any spraying area during spraying operations. Portable electric lamps, if used during cleaning or repairing operations, shall be of the type approved for hazardous Class I locations. (a) Location - Spray Booth: On or about 10/16/14, the employer was using portable lamps during spraying operations that were not approved for Class I Hazardous Locations.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(b)(6): Frontal area. Each spray booth having a frontal area larger than 9 square feet did not have a metal deflector or curtain not less than 2 1/2 inches deep installed at the upper outer edge of the booth over the opening. (a) Location - Spray Booth: On or about 10/16/14, the employer failed to ensure that the spray booth was equipped with a metal deflector or curtain at the upper outer edge of the booth over the opening.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.107 B05 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.107(b)(5)(i): Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. (a) Location - Spray Booth: On or about 10/16/14, the employer failed to provide a visible gauge or audible alarm on the spray booth to indicate that the required air velocity is maintained.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.307 C
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) Location - Bag House: On or about 10/16/14, portable lighting in the Bag House was not approved for a hazardous location.
Recent events (2)
- — I (S) $800
- — Z (S) $2000
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $400.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (a) Location Facility: On or about 10/16/14, the employer did not have a written hazard communication program.
Recent events (2)
- — I (O) $400
- — Z (S) $1600
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): Employer did not have a safety data sheet in the workplace for each hazardous chemical which they use: (a) Location - Facility: On or about 10/16/14, the employer failed to have a safety data sheet for each hazardous chemical in the workplace.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections in this industry (NAICS 321999)
LAURINBURG, NC—2026-07-14
161549 - AMERICAN WOOD FIBERS, INC.
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH WILKESBORO, NC—2026-07-07
161501 - MILLER BEE SUPPLY, INC.
MIAMI, FL—2026-06-26
FLORIDA LUMBER COMPANY
PLATO, MN—2026-06-25
111471 - GREAT OAK EQUINE
More inspections in MA
BELLINGHAM, MA—2026-07-16
BELLINGHAM DEPARTMENT OF PUBLIC WORKS
PLYMOUTH, MA—2026-07-15
TECH-ETCH, INC.
WESTFIELD, MA—2026-07-15
BOISE CASCADE BUILDING MATERIALS DISTRIBUTION, L.L.C.
QUINCY, MA—2026-07-15
UNITEDWOR VM CONTRACTOR CORP
FALL RIVER, MA—2026-07-15
CRESCO LABS, INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340019678.