Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: STOLTZFUS BUILDERS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STOLTZFUS BUILDERS in 247 BROAD STREET, MONTOURSVILLE, PA 17754 (NAICS 238140). OSHA activity number 340020858.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stoltzfus Builders — free Get an email when a new federal OSHA severe-injury report for Stoltzfus Builders is published. One employer, no account, unsubscribe in one click.
Establishment
STOLTZFUS BUILDERS
Site address
247 BROAD STREET
City
MONTOURSVILLE
State
PA
ZIP
17754
Mailing
126 COYOTE LANE, MILL HALL, PA 17751
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

6 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 23, 2015
Abate by
Feb 4, 2015
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:     a) 247 Broad Street, Montoursville, PA; Employees were laying 8 inch cinderblock on steel tubular scaffolding that was not provided with base plates or another adequate firm foundation, on or about 10/20/2014.    Abatement Certification Required
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.451 C02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 23, 2015
Abate by
Feb 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement:   a) 247 Broad Street, Montoursville, PA; Employees were installing 8 inch cinderblock while working on scaffolding that was supported by cinderblocks that did not have the strength or integrity to support the steel tubular scaffolding, on or about 10/20/2014.   Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 23, 2015
Abate by
Feb 4, 2015
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:     a) 247 Broad Street, Montoursville, PA; Employees were laying 8 inch cinderblock while working on steel tubular scaffolding that ranged in height from 14 feet 2 inches to 15 feet 11 inches without the use of fall protection, on or about 10/20/2014.     Abatement Certification Required
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.454 B

Serious Gravity 1 1 instance 5 exposed
Issued
Jan 23, 2015
Abate by
Feb 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question:   a) 247 Broad Street, Montoursville, PA; Employees that erected the scaffolding were not trained by a competent person to recognize hazards associated with scaffold erection, on or about 10/20/2014.   Abatement Certification Required
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 C02

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 23, 2015
Abate by
Feb 4, 2015
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:     a) 247 Broad Street, Montoursville, PA; Employees were installing 8 inch block on steel tubular scaffolding that was not provided with cross bracing, on or about 10/20/2014.     Abatement Certification Required
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.20 B01

Other-than-serious 1 instance 8 exposed
Issued
Jan 23, 2015
Abate by
Feb 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(1): The employer did not initiate and maintain accident prevention programs as necessary to comply with this part:   a) 247 Broad Street, Montoursville, PA; The employer did not initiate and maintain an accident prevention program for employees that were installing 8 inch cinderblock while working on steel tubular scaffolding, on or about 10/20/2014.   Abatement Certification Required
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Stoltzfus Builders's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340020858.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.