TEMPLE, TX —
OSHA Inspection: LJT TEXAS L.P.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LJT TEXAS L.P. in 3601 EBERHARDT ROAD, TEMPLE, TX 76504 (NAICS 331210). OSHA activity number 340021682.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LJT TEXAS L.P.
- Site address
- 3601 EBERHARDT ROAD
- City
- TEMPLE
- State
- TX
- ZIP
- 76504
- Mailing
- 3601 EBERHARDT ROAD, TEMPLE, TX 76504
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331210
- Employees
- 125
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.23 A02
- Issued
- Nov 19, 2014
- Abate by
- Nov 25, 2014
- Penalty
- Initial $3,600 · Current $2,160 Reduced
General-duty citation text
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening. On or about 20 October 2014, and at times prior thereto, employees performed maintenance duties from two elevated platforms with unguarded ladderway floor openings, exposing the employees to a fall hazard of approximately 104 inches or 8 feet, 8 inches to the concrete floor below. 1) The work platform for the filter bed has a ladder for access in which the opening is not guarded and is approximately 8 feet, 8 inches from the concrete floor below. 2) The work platform for the cooling tower has a ladder for access in which the opening is not guarded and is approximately 8 feet, 8 inches from the concrete floor below.
Recent events (2)
- — I (S) $2160
- — Z (S) $3600
1910.253 B02 IV
- Issued
- Nov 19, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use. On or about 20 October 2014, and at times prior thereto, two full cylinders in storage within the plant did not have the valve protection caps on them, exposing the employees working within the area to a struck by hazard due to the valve and stem suffering damage and a catastrophic release of the compressed gas.
Recent events (2)
- — I (O) $1377
- — Z (S) $2295
1910.157 C01
- Issued
- Nov 19, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries. On or about 20 October 2014, and at times prior thereto, fire extinguishers mounted on the wall near areas A10 and A12 of the production floor were not identified so that they would be readily accessible, exposing the employees working in the area to various fire hazards.
Recent events (2)
- — I (O) $1377
- — Z (S) $2295
1910.303 G01 I A
- Issued
- Nov 19, 2014
- Penalty
- Initial $2,295 · Current $1,377 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910. On or about 20 October 2014, and at times prior thereto, a stack of wood dunnage was stored under or within 36 inches to the front of an electrical breaker panel, control panel, and disconnect switch thus blocking access and exposing employees to electrical hazards of approximately 480 volts.
Recent events (2)
- — I (O) $1377
- — Z (S) $2295
1910.305 B01 II
- Issued
- Nov 19, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. On or about 20 October 2014, and at times prior thereto, employees utilized hand-held power tools at a work bench within the Maintenance Shop in which the electrical outlet had a missing knockout, exposing employees to electrical hazards of approximately 120 volts.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at LJT Texas L.P.
View LJT Texas L.P.'s full OSHA safety record →
More inspections in this industry (NAICS 331210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340021682.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.