OSHA Inspection: LJT TEXAS L.P.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LJT TEXAS L.P. in 3601 EBERHARDT ROAD, TEMPLE, TX 76504 (NAICS 331210). OSHA activity number 340021682.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch LJT Texas L.P. — free Get an email when a new federal OSHA severe-injury report for LJT Texas L.P. is published. One employer, no account, unsubscribe in one click.
Establishment
LJT TEXAS L.P.
Site address
3601 EBERHARDT ROAD
City
TEMPLE
State
TX
ZIP
76504
Mailing
3601 EBERHARDT ROAD, TEMPLE, TX 76504
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
125
Ownership type
A

5 citations on file for this inspection.

1910.23 A02

Serious Gravity 5 2 instances 8 exposed
Issued
Nov 19, 2014
Abate by
Nov 25, 2014
Penalty
Initial $3,600 · Current $2,160 Reduced
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening.    On or about 20 October 2014, and at times prior thereto, employees performed maintenance duties from two elevated platforms with unguarded ladderway floor openings, exposing the employees to a fall hazard of approximately 104 inches or 8 feet, 8 inches to the concrete floor below.  1) The work platform for the filter bed has a ladder for access in which the opening is not guarded and is approximately 8 feet, 8 inches from the concrete floor below.  2) The work platform for the cooling tower has a ladder for access in which the opening is not guarded and is approximately 8 feet, 8 inches from the concrete floor below.
Recent events (2)
  • — I (S) $2160
  • — Z (S) $3600

1910.253 B02 IV

Other-than-serious 1 instance 8 exposed
Issued
Nov 19, 2014
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.    On or about 20 October 2014, and at times prior thereto, two full cylinders in storage within the plant did not have the valve protection caps on them, exposing the employees working within the area to a struck by hazard due to the valve and stem suffering damage and a catastrophic release of the compressed gas.
Recent events (2)
  • — I (O) $1377
  • — Z (S) $2295

1910.157 C01

Other-than-serious 1 instance 125 exposed
Issued
Nov 19, 2014
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.    On or about 20 October 2014, and at times prior thereto, fire extinguishers mounted on the wall near areas A10 and A12 of the production floor were not identified so that they would be readily accessible, exposing the employees working in the area to various fire hazards.
Recent events (2)
  • — I (O) $1377
  • — Z (S) $2295

1910.303 G01 I A

Other-than-serious 1 instance 8 exposed
Issued
Nov 19, 2014
Penalty
Initial $2,295 · Current $1,377 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910.     On or about 20 October 2014, and at times prior thereto, a stack of wood dunnage was stored under or within 36 inches to the front of an electrical breaker panel, control panel, and disconnect switch thus blocking access and exposing employees to electrical hazards of approximately 480 volts.
Recent events (2)
  • — I (O) $1377
  • — Z (S) $2295

1910.305 B01 II

Other-than-serious 1 instance 8 exposed
Issued
Nov 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.    On or about 20 October 2014, and at times prior thereto, employees utilized hand-held power tools at a work bench within the Maintenance Shop in which the electrical outlet had a missing knockout, exposing employees to electrical hazards of approximately 120 volts.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

View LJT Texas L.P.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340021682.