SCENERY HILL, PA ·
OSHA Inspection: HALLIBURTON ENERGY SERVICES
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HALLIBURTON ENERGY SERVICES in ZORRO PAD, 350 KINDER ROAD, SCENERY HILL, PA 15360 (NAICS 213111). OSHA activity number 340024470.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HALLIBURTON ENERGY SERVICES
- Site address
- ZORRO PAD, 350 KINDER ROAD
- City
- SCENERY HILL
- State
- PA
- ZIP
- 15360
- Mailing
- 121 CHAMPION WAY, SUITE 200, CANONSBURG, PA 15317
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 4
- Ownership type
- Private (A)
Citations
1 citation on file for this inspection.
1910.24 B
- Issued
- Dec 24, 2014
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.24(b): Fixed stairs were not provided for access from one structure level to another where operations necessitated regular travel between levels, and for access to operating platforms at any equipment which requires attention routinely during operations: (a) Zorro Pad, 350 Kinder Road, Scenery Hill, PA: On or about October 19, 2014, the employer did not have its employees working from the Centrifugal Services Inc. (CSI) Model WSM-03 Vertical Cuttings Dryer work platform to help assemble the incoming auger into place at the top of the dryer. Three employees were working at assembling the dryer and at least one of the three employees was standing on the 3 inch by 3 inch by 1/2 inch wide clips (ears) that were welded to the supporting posts of the machine. An employee lost his balance while standing on two of these clips (ears) and went to step back off of the clips (ears). In this process, the employee caught the top of the steel drip pan edge (with his one foot), which is less than a 1/16 inch thick and in the process lost his balance, fell and broke his ankle.
Recent events (2)
- · I (O) $7000
- · Z (S) $7000
More inspections at Halliburton Energy Services