PHILADELPHIA, PA —
OSHA Inspection: SETAG CONSTRUCTION CO., INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of SETAG CONSTRUCTION CO., INC. in 1901 LOMBARD STREET, PHILADELPHIA, PA 19146 (NAICS 238140). OSHA activity number 340025675.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SETAG CONSTRUCTION CO., INC.
- Site address
- 1901 LOMBARD STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19146
- Mailing
- 1670 SHEFLEY LANE, COLLEGEVILLE, PA 19426
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 25
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.25 A
- Issued
- Mar 26, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $1,200 · Current $750 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a) Jobsite, 1901 Lombard St., Philadelphia - The work area around the scaffolds at the front of the building, including building entrances was not kept free of bricks and debris, exposing employees to trip hazards. Observed on or about 10/17/14.
Recent events (2)
- — I (O) $750
- — Z (S) $1200
1926.451 E01
- Issued
- Mar 26, 2015
- Penalty
- Initial $4,000 · Current $4,000
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) Jobsite, 1901 Lombard St., Philadelphia - A ladder or other safe means of access was not provided to employees performing masonry operations from a fabricated frame scaffold. An employee used the side frames and cross-braces as a means of access/egress, thus being exposed to fall hazards up to approximately twenty six (26) feet above ground level. Observed on or about 10/17/14. SETAG CONSTRUCTION CO., INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.451(e)(6) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 946153, CITATION 1 ITEM 1, AND WAS AFFIRMED AS A FINAL ORDER ON 12/04/13 WITH RESPECT TO A WORKPLACE LOCATED AT 160 DEKALB PIKE, KING OF PRUSSIA, PA 19406.
Recent events (2)
- — I (S) $4000
- — Z (R) $4000
1926.451 C02
- Issued
- Mar 26, 2015
- Abate by
- Apr 1, 2015
- Penalty
- Initial $4,000 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation. a) Jobsite, 1901 Lombard St., Philadelphia - The front legs of two of the scaffold frames were placed on planks on top of the sixth level. Employees working on the seventh level of the fabricated frame scaffold approximately forty six(46) feet above ground level were exposed to a scaffold collapse hazard. Observed on or about 10/21/14. SETAG CONSTRUCTION CO., INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.451(C)(2) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 752682, CITATION 1 ITEM 2, AND WAS AFFIRMED AS A FINAL ORDER ON 5/9/2013 WITH RESPECT TO A WORKPLACE LOCATED AT 1845 FITZWATER STREET, PHILADELPHIA PA 19146.
Recent events (2)
- — I (R) $0
- — Z (R) $4000
1926.451 G01 VII
- Issued
- Mar 26, 2015
- Penalty
- Initial $5,600 · Current $5,250 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) Jobsite, 1901 Lombard St., Philadelphia - The employer did not ensure that an employee performing masonry operations from the 5th level of a fabricated frame scaffold was protected by the use of personal fall arrest systems or guardrail systems, exposing the employee to a fall hazard of approximately twenty six (26) feet. Observed on or about 10/17/14. SETAG CONSTRUCTION CO., INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.451(g)(1)(vii) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 752682, CITATION 1 ITEM 3, AND WAS AFFIRMED AS A FINAL ORDER ON 5/9/2013 WITH RESPECT TO A WORKPLACE LOCATED AT 1845 FITZWATER STREET, PHILADELPHIA PA 19146.
Recent events (2)
- — I (R) $5250
- — Z (R) $5600
1926.501 B04 II
- Issued
- Mar 26, 2015
- Penalty
- Initial $5,600 · Current $4,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes by covers: a) Jobsite, 1901 Lombard St., Philadelphia - The holes in the ground around the basement doors along the front of the building were not covered, exposing employees to a fall hazard of six feet. Observed on or about 10/21/14. SETAG CONSTRUCTION CO., INC. WAS PREVIOUSLY CITED FOR A VIOLATION OF THIS OCCUPATIONAL SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT STANDARD 1926.451(C)(2) WHICH WAS CONTAINED IN OSHA INSPECTION NUMBER 752682, CITATION 2 ITEM 1, AND WAS AFFIRMED AS A FINAL ORDER ON 5/9/2013 WITH RESPECT TO A WORKPLACE LOCATED AT 1845 FITZWATER STREET, PHILADELPHIA PA 19146.
Recent events (2)
- — I (S) $4000
- — Z (R) $5600
More inspections at Setag Construction CO., INC.
View Setag Construction CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340025675.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.