Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STE. GENEVIEVE NURSING HOME

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STE. GENEVIEVE NURSING HOME in 2330 S. 12TH STREET, SAINT LOUIS, MO 63104 (NAICS 238190). OSHA activity number 340026236.

Watch STE. Genevieve Nursing Home — free Get an email when a new federal OSHA severe-injury report for STE. Genevieve Nursing Home is published. One employer, no account, unsubscribe in one click.
Site address
2330 S. 12TH STREET
City
SAINT LOUIS
State
MO
ZIP
63104
Mailing
10733 LEEBUR DR, SAINT LOUIS, MO 63124
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
4
Ownership type
A

7 citations on file for this inspection.

1926.21 B02

Deleted Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $0.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury:  At the job site, employee(s) were not instructed to recognize the following hazards:  a/  When appropriate eye protection was required.  b/  When appropriate guarding was required for a cross-cut table saw.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.503 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(a)(1):  The employer did not provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards:  a/  At the job site, employee(s) applying a sealant and performing tuckpointing work up on a low sloped roof were not instructed to recognize the fall hazard or means of abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.102 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.102(a)(1): Employee(s) were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents:    a/  At the job site, employee(s) operating an unguarded, Sears Craftsman 10" Table Saw, m/n 113221740, s/n 9629070316, were not provided with or used suitable eye protection.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.304 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.304(h)(1): Each circular crosscut table saw was not guarded by a hood which met all the requirements of paragraph (i)(1) of this section for hoods for circular ripsaws:    a/  At the job site, a/  At the job site, employee(s) operating an unguarded, Sears Craftsman 10" Table Saw, m/n 113221740, s/n 9629070316, were not provided with or used suitable eye protection.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1800.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities six feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system:    a/  At the job site, employee(s) applying a sealant and performing tuckpointing work along the west, exterior roof of the building were not provided with any form of conventional fall protection.  The fall distance to the sidewalk below was approximately 30 feet.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(1): When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least three feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    a/  At the job site, the side rails belonging to a portable extension ladder leading up to the low sloped roof from the second floor extended beyond the edge by approximately one foot.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2800

1926.1053 B04

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed:  a/  At the job site, the Rib-Jib Portable Step Ladder was used by employee(s) in the closed position.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340026236.