NORTH RICHLAND HILLS, TX ·
OSHA Inspection: DALLAS QUALITY GUTTERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DALLAS QUALITY GUTTERS, INC. in 7657 BLVD. 26, NORTH RICHLAND HILLS, TX 76180 (NAICS 238170). OSHA activity number 340026269.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DALLAS QUALITY GUTTERS, INC.
- Site address
- 7657 BLVD. 26
- City
- NORTH RICHLAND HILLS
- State
- TX
- ZIP
- 76180
- Mailing
- 690 NORTHWARD DR, ROYSE CITY, TX 75189
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Mar 17, 2015
- Abate by
- Apr 14, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns. On or about October 20, 2014, the employer did not ensure personal protective equipment, such as hard hats were being worn by employees while working underneath other employees. Employees were exposed to struck by hazards.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1926.405 A02 II I
- Issued
- Mar 17, 2015
- Penalty
- Initial $1,020 · Current $510 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage. On or about October 20, 2014, employees used portable hand tools energized with an electrical extension cord that was not protected from vehicular traffic, exposing employees to electrical shock hazards.
Recent events (2)
- · I (S) $510
- · Z (S) $1020
1926.416 E01
- Issued
- Mar 17, 2015
- Abate by
- Apr 14, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used. On or about October 20, 2014, employees were operating portable hand tools energized with a worn and damaged electrical extension cord, exposing employees to electrical shock hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B02 I
- Issued
- Mar 17, 2015
- Abate by
- Apr 14, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.501(b)(2)(i): Each employee who was constructing a leading edge 6 feet or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems: Note: If the employer could demonstrate that it was infeasible or created a greater hazard to use these systems, a fall protection plan meeting the requirements of paragraph (k) of 1926.502 should have been developed and implemented. On or about October 20, 2014, employees installing gutters onto a restaurant were working from the roof and roof edges without fall protection exposing the employees to falls of more than 15 feet to the concrete below.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.1053 B01
- Issued
- Mar 17, 2015
- Penalty
- Initial $1,700 · Current $890 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access. On or about October 20, 2014, employees performing installation activities accessed the roof area with extension ladders that the side rails did not extend at least 3 feet above the upper landing surface exposing them to a fall hazard of approximately 15 feet to the concrete below. a) Werner extension ladder, on the south side of restaurant, facing north, positioned below the guttering. b) Werner extension ladder, on the north side of restaurant, facing south, next to side walk, positioned below the guttering.
Recent events (2)
- · I (S) $890
- · Z (S) $1700
More inspections in this industry (NAICS 238170)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340026269.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.