Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DALLAS QUALITY GUTTERS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DALLAS QUALITY GUTTERS, INC. in 7657 BLVD. 26, NORTH RICHLAND HILLS, TX 76180 (NAICS 238170). OSHA activity number 340026269.

Watch Dallas Quality Gutters, INC. — free Get an email when a new federal OSHA severe-injury report for Dallas Quality Gutters, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7657 BLVD. 26
City
NORTH RICHLAND HILLS
State
TX
ZIP
76180
Mailing
690 NORTHWARD DR, ROYSE CITY, TX 75189
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns.       On or about October 20, 2014, the employer did not ensure personal protective equipment, such as hard hats were being worn by employees while working underneath other employees.  Employees were exposed to struck by hazards.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1926.405 A02 II I

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1020.00 · Current $510.00 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables used for temporary wiring were not protected from damage.    On or about October 20, 2014, employees used portable hand tools energized with an electrical extension cord that was not protected from vehicular traffic, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $510
  • — Z (S) $1020

1926.416 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used.  On or about October 20, 2014, employees were operating portable hand tools energized with a worn and damaged electrical extension cord, exposing employees to electrical shock hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.501(b)(2)(i): Each employee who was constructing a leading edge 6 feet or more above lower levels was not protected from falling by guardrail systems, safety net systems, or personal fall arrest systems:  Note:  If the employer could demonstrate that it was infeasible or created a greater hazard to use these systems, a fall protection plan meeting the requirements of paragraph (k) of 1926.502 should have been developed and implemented.      On or about October 20, 2014, employees installing gutters onto a restaurant were working from the roof and roof edges without fall protection exposing the employees to falls of more than 15 feet to the concrete below.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 2 instances 3 exposed
Issued
Penalty
Initial $1700.00 · Current $890.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access.    On or about October 20, 2014, employees performing installation activities accessed the roof area with extension ladders that the side rails did not extend at least 3 feet above the upper landing surface exposing them to a fall hazard of approximately 15 feet to the concrete below.      a)  Werner extension ladder, on the south side of restaurant, facing north, positioned below the guttering.  b)  Werner extension ladder, on the north side of restaurant, facing south, next to side walk, positioned below the guttering.
Recent events (2)
  • — I (S) $890
  • — Z (S) $1700

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340026269.