BRISTOL, NH ·
OSHA Inspection: GILPATRIC METAL RECYCLING, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GILPATRIC METAL RECYCLING, LLC. in 201 ADEL ROAD, BRISTOL, NH 03222 (NAICS 423930). OSHA activity number 340027275.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GILPATRIC METAL RECYCLING, LLC.
- Site address
- 201 ADEL ROAD
- City
- BRISTOL
- State
- NH
- ZIP
- 03222
- Mailing
- 201 ADEL ROAD, BRISTOL, NH 03222
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 6
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.151 C
- Issued
- Oct 28, 2014
- Abate by
- Nov 3, 2014
- Penalty
- Initial $2,000 · Current $600 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a. Site - On or about October 20, 2014, an eyewash station was not provided to employees who were assigned to work with used batteries which contained corrosives materials.
Recent events (2)
- · I (S) $600
- · Z (S) $2000
1910.303 G01
- Issued
- Oct 28, 2014
- Abate by
- Nov 3, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Instance a. Shop Building - On or about October 20, 2014, the green air compressor's electrical emergency disconnect was blocked and not made accessible during emergency or maintenance events. Instance b. Shop Building - On or about October 20, 2014, the electrical service panel for the building was blocked and not made accessible during emergency or maintenance events. Instance c. Shop Building - On or about October 20, 2014, the alligator metal shear cutting machine's electrical emergency disconnect was blocked and not made accessible during emergency or maintenance events.