OSHA Inspection: BEMIS PERFORMANCE PACKAGING, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BEMIS PERFORMANCE PACKAGING, INC. in 1309 BEMIS RD, LANCASTER, WI 53813 (NAICS 323112). OSHA activity number 340027341.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bemis Performance Packaging, INC. for free Get an email when a new federal OSHA severe-injury report for Bemis Performance Packaging, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1309 BEMIS RD
City
LANCASTER
State
WI
ZIP
53813
Mailing
1309 BEMIS RD, LANCASTER, WI 53813
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323112
Employees
180
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 2 instances 15 exposed
Issued
Feb 9, 2015
Abate by
Mar 31, 2015
Penalty
Initial $7,000 · Current $5,000 Reduced

Hazardous substances 10602170

OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to deflagration, explosion, or other fire hazards while working at or near printing press dryer units that were not adequately designed to prevent or minimize employee exposure in the event of an explosion, deflagration, or other fire event:    On or about October 21, 2014, employee(s) were exposed to deflagration, explosion, or other fire hazards such as, but not limited to:    a) The dryer unit for press 6 (PCMC Model 7450) lacked a means of venting explosions and/or deflagrations to a safe location.    Among other methods, a feasible method to correct these hazards would be to comply with the National Fire Protection Association (NFPA) 68 "Standard on Explosion Protection by Deflagration Venting" and NFPA 86 "Standard for Ovens and Furnaces".  Sections 6.6.1 and 6.6.2 of NFPA 68 and Section 5.3.6 of NFPA 86 cover explosion and deflagration venting.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $7000