Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: BASIL FITZSIMONS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BASIL FITZSIMONS in 2475 HIGGINS RD., HOFFMAN ESTATES, IL 60192 (NAICS 238130). OSHA activity number 340027739.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Basil Fitzsimons for free Get an email when a new federal OSHA severe-injury report for Basil Fitzsimons is published. One employer, no account, unsubscribe in one click.
Establishment
BASIL FITZSIMONS
Site address
2475 HIGGINS RD.
City
HOFFMAN ESTATES
State
IL
ZIP
60192
Mailing
8006 W. SUMMERDALE AVE., CHICAGO, IL 60656
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
5
Ownership type
Private (A)

12 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 12, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(b)(1):  Each platform on all working levels was not fully planked or decked between front uprights and the guardrail supports:        a)   Employees working from frame scaffolding were exposed to fall hazards of approximately 17.2 feet where the scaffold platform was not fully decked.      No abatement certification or documentation is required for this item.
Recent events (3)
  • · A (S) $2800
  • · I (S) $1100
  • · Z (S) $2800

1926.451 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.451(c)(1):  Supported scaffold(s) with a height to base width (including outrigger supports) ratio greater than four to one (4:1) was not restrained from tipping by guying, tying, bracing, or equivalent means:      a)  Employees were exposed to fall hazards of approximately 17.2 feet while working on a frame scaffold which was not restrained from tipping by any means.        No abatement certification or documentation is required for this item.
Recent events (3)
  • · A (S) $2000
  • · I (S) $950
  • · Z (S) $2000

1926.451 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2):  Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:      a)  Supported scaffold legs did not bear on base plates.      No abatement certification or documentation is required for this item.
Recent events (3)
  • · A (S) $0
  • · I (S) $1100
  • · Z (S) $0

1926.451 C02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 12, 2015
Abate by
Jan 16, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(c)(2)(iv):  Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use:       a)  Employees were exposed to fall hazards of approximately 17.2 feet, while performing carpentry work from a sheet of plywood that was placed on the forks of a JLG all terrain forklift, model number G6-42A, and utilized as an elevated work platform.         In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • · A (S) $2800
  • · I (S) $1100
  • · Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 12, 2015
Abate by
Jan 16, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:      a)  Employees working from frame scaffolding were exposed to fall hazards of approximately 17.2 feet.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • · A (S) $2800
  • · I (S) $1100
  • · Z (S) $2800

1926.501 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 12, 2015
Abate by
Jan 16, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(1):  Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:      a)  Employees performing carpentry work were exposed to fall hazards of approximately 17.2 feet      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (3)
  • · A (S) $2800
  • · I (S) $1100
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 12, 2015
Abate by
Jan 16, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed:      a)  Employees were using an extension ladder which did not extend 3 feet above the upper landing being accessed.       In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • · A (S) $2000
  • · I (S) $950
  • · Z (S) $2000

1926.1053 B04

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 12, 2015
Abate by
Jan 16, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.1053(b)(4):  Ladder(s) were used for purposes other than the purpose for which they were designed:    a)  Employees were exposed to fall hazards while using an a-frame ladder without its metal spreaders or locking devices in the open position on the edge of an unprotected working surface approximately 17.2 feet high.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • · A (S) $2800
  • · I (S) $1100
  • · Z (S) $2800

1926.300 B01

Other-than-serious 1 instance 5 exposed
Issued
Jan 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.300(b)(1):  Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use:   a)  Employees were using unguarded DeWalt grinder while performing carpentry work.    No abatement certification or documentation is required for this item.
Recent events (3)
  • · A (O) $0
  • · I (O) $0
  • · Z (O) $0

1926.403 B02

Other-than-serious 1 instance 4 exposed
Issued
Jan 12, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    a)  Employees engaged in painting activity were using a relocatable power tap in an outdoor setting to power tools onsite.    No abatement certification or documentation is required for this item.
Recent events (3)
  • · A (O) $0
  • · I (O) $0
  • · Z (O) $0

1926.404 F06

Other-than-serious 1 instance 5 exposed
Issued
Jan 12, 2015
Abate by
Jan 16, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.404(f)(6):  The path to ground from circuits, equipment, or enclosures was not permanent and continuous:  a)  Employees were using electrical power tools which were plugged into extension cords which was missing a ground pin.   No abatement certification or documentation is required for this item.
Recent events (3)
  • · A (O) $0
  • · I (O) $0
  • · Z (O) $0

1926.405 B02

Other-than-serious 4 instances 5 exposed
Issued
Jan 12, 2015
Abate by
Jan 16, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.405(b)(2): All pull boxes, junction boxes, or fittings were not provided with covers:  a) Employees were exposed to electrical hazards while utilizing a receptacle that had not cover.    No abatement certification or documentation is required for this item.
Recent events (3)
  • · A (O) $0
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340027739.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.