MC FARLAND, WI —
OSHA Inspection: MADISON ALUMINUM PRODUCTS, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MADISON ALUMINUM PRODUCTS, LLC in 4219 TRIANGLE ST., MC FARLAND, WI 53558 (NAICS 238990). OSHA activity number 340029537.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MADISON ALUMINUM PRODUCTS, LLC
- Site address
- 4219 TRIANGLE ST.
- City
- MC FARLAND
- State
- WI
- ZIP
- 53558
- Mailing
- 4219 TRIANGLE ST., MC FARLAND, WI 53558
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1053 A01 I
- Issued
- Jan 30, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $1,360 · Current $952 Reduced
General-duty citation text
29 CFR 1926.1053(a)(1)(i): Self supporting portable ladders were not capable of supporting, without failure, at least four times the maximum intended load. Ladders built and tested in conformance with the applicable provisions of Appendix A of this subpart will be deemed to meet this requirement: On or about October 21, 2014, portable aluminum stepladders repaired by the employer had not been tested or approved for use by the manufacturer. Repaired ladders included: a) Ladder 1- Welded foot, both sides; support brackets have welded plates b) Ladder 2- Rivets replaced by screws on frame; left and right frames welded c) Ladder 4- Support brackets loose, welded on both sides, screws replacing rivets on right side of frame d) Ladder 5- Welds at all support brackets, screws replacing rivets at feet e) Ladder 7- Extensive welds on both sides of frame; brackets welded on both sides; welds on both feet f) Ladder 8- Extensive welds on both sides of frame; brackets welded on both sides; welds on both feet
Recent events (2)
- — I (S) $952
- — Z (S) $1360
1926.1053 B18
- Issued
- Jan 30, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(18): Ladder repairs did not restore the ladder to a condition meeting its original design criteria, before the ladder was returned to use: On or about October 21, 2014, portable aluminum ladders were put in use without having been restored to their original designs. Repaired ladders in use included: a) Ladder 1- Welded foot, both sides; support brackets have welded plates b) Ladder 2- Rivets replaced by screws on frame; left and right frames welded c) Ladder 4- Support brackets loose, welded on both sides, screws replacing rivets on right side of frame d) Ladder 5- Welds at all support brackets, screws replacing rivets at feet e) Ladder 7- Extensive welds on both sides of frame; brackets welded on both sides; welds on both feet f) Ladder 8- Extensive welds on both sides of frame; brackets welded on both sides; welds on both feet