BATAVIA, OH —
OSHA Inspection: C & O CONSTRUCTION, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C & O CONSTRUCTION, LLC in 4402 HARTMAN LANE, BATAVIA, OH 45103 (NAICS 238310). OSHA activity number 340030147.
Where did this inspection happen?
- Establishment
- C & O CONSTRUCTION, LLC
- Site address
- 4402 HARTMAN LANE
- City
- BATAVIA
- State
- OH
- ZIP
- 45103
- Mailing
- 6587 HENDRICKSON RD, MIDDLETOWN, OH 45044
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 3
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 E01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. An employee was observed climbing the crossbar of a Tubular Welded Frame Scaffold that was not equipped with a ladder to gain access to the working platform. Employee's were expose to a fall hazard approximately 17' to the ground below.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.451 G01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: Employees were performing plastering operations at the an open end of a tubular welded frame scaffold while not using any type of fall protection system. Potential fall height was measured to be 17 feet to the ground below.
Recent events (2)
- — I (S) $1400
- — Z (S) $2800
1926.452 C03
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(3): Frames and panels shall be joined together vertically by coupling or stacking pins or equivalent means. Employees were working from a Tubular Welded Frame Scaffold that was not erected in accordance with manufacture's specification using wire throughout the scaffolding system as a staking pin to join together the scaffold frames.
Recent events (2)
- — I (O) $0
- — Z (S) $2800
More inspections in this industry (NAICS 238310)
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
IRVINE, CA—2026-07-10
COAST BUILDING PRODUCTS
FRANCESTOWN, NH—2026-07-10
D&D INSULATION, LLC
DOWNINGTOWN, PA—2026-07-09
CAPITAL INTERIOR, LLC
More inspections in OH
OXFORD, OH—2026-07-13
R&R SIDING LLC
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
CAMDEN, OH—2026-07-13
ALBERTO MORALES
HARRISON, OH—2026-07-10
WEBER FAMILY FARMS LLC
JEFFERSON, OH—2026-07-10
LAKE CITY PLATING LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340030147.