Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: OLNEY FERTILIZER CO., INC.

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of OLNEY FERTILIZER CO., INC. in 103 WARD STREET, OLNEY, TX 76374 (NAICS 424910). OSHA activity number 340031541.

Watch Olney Fertilizer CO., INC. — free Get an email when a new federal OSHA severe-injury report for Olney Fertilizer CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
103 WARD STREET
City
OLNEY
State
TX
ZIP
76374
Mailing
RT 3 396 TERREL ROAD, OLNEY, TX 76374
Inspection type
Special Programs (K)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424910
Employees
2
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $720.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazards of chemical burns and inhalation of anhydrous ammonia.  On or about October 23, 2014, and at times prior thereto, at the anhydrous storage tank facility employees working with and in close proximity of a large 12,000 gallon liquid anhydrous ammonia storage / service tank were exposed to the hazards of contact with liquid ammonia and inhalation of vapor from leaking or failed ammonia systems.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1800

1910.111 B03 II A

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $720.00 Reduced
29 CFR 1910.111(b)(3)(ii)(a): Each container or system covered in paragraphs (c), (f), (g), and (h) of this section were not marked with a notation "Anhydrous Ammonia".  On or about October 23, 2013 and at times prior thereto, the employer did not ensure that the main anhydrous ammonia storage/service tanks were labeled, with the visible words "Anhydrous Ammonia".
Recent events (2)
  • — I (S) $720
  • — Z (S) $1800

1910.111 B10 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $720.00 Reduced
29 CFR 1910.111(b)(10)(ii): Stationary ammonia storage installation(s) did not have at least two suitable gas masks in readily-accessible locations:  On or about October 23, 2014, and at times prior thereto, at the anhydrous storage tank facility, employees working with and in close proximity of a large 12,000 gallon liquid anhydrous ammonia storage/service tank and portable nurse tanks were not provided with gas masks exposing the employees to the hazards of inhalation of vapor from leaking or failed ammonia systems.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1800

1910.111 B10 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $720.00 Reduced
29 CFR 1910.111(b)(10)(iii): Stationary storage installations did not have an easily accessible shower or a 50-gallon drum of water:  On or about October 23, 2014, and at times prior thereto, at the anhydrous storage tank facility, employees working with and in close proximity of a large 12,000 gallon liquid anhydrous ammonia storage/service tank and portable nurse tanks were not provided with an emergency water source exposing the employees to the hazards of contact with liquid ammonia from leaking or failed ammonia systems.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1800

1910.111 G06 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $720.00 Reduced
29 CFR 1910.111(g)(6)(iv): All vehicles shall carry a can containing 5 gallons or more of water:  On or about October 23, 2014, and at times prior thereto, at the anhydrous storage tank facility, employees working with anhydrous ammonia portable nurse tanks were not provided with an emergency water source such as but not limited to an attached water bag exposing the employees to the hazards of contact with liquid ammonia from leaking or failed ammonia systems.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1800

1910.219 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1800.00 · Current $720.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  On or about October 23, 2014 and at times prior thereto, the employer did not ensure that the anhydrous storage / service tank compressor belts and pulleys were guarded exposing the employees to caught-in and amputation hazards from the rotating parts.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340031541.