Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: ANC NORTHERN JOINT VENTURE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANC NORTHERN JOINT VENTURE, LLC in LOWER GOVERNMENT HILL HOUSING, KODIAK, AK 99619 (NAICS 238160). OSHA activity number 340034073.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ANC Northern Joint Venture, LLC for free Get an email when a new federal OSHA severe-injury report for ANC Northern Joint Venture, LLC is published. One employer, no account, unsubscribe in one click.
Site address
LOWER GOVERNMENT HILL HOUSING
City
KODIAK
State
AK
ZIP
99619
Mailing
2627 C STREET SUITE 302, ANCHORAGE, AK 99503
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.451 C02

Serious Gravity 1 2 instances 5 exposed
Issued
Nov 7, 2014
Abate by
Dec 9, 2014
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation.  Coast Guard Lower Government Housing Project; on or about 20 October 2014 and times prior thereto; the employer did not ensure that a tubular welded frame scaffold was erected on footings that would not settle; or cause them to become displaced. Two instances were noted where scaffolds were erected without base plates and mud sills. Scaffolds were positioned on a grassy surface. This condition exposed employees to a fall and struck by hazards in the event that the scaffold collapsed.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1020

1926.452 C02

Serious Gravity 1 2 instances 5 exposed
Issued
Nov 7, 2014
Abate by
Dec 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.452(c)(2): All brace connections were not secured.  Coast Guard Lower Government Housing Project; on or about 20 October 2014 and times prior thereto; the employer did not ensure that a tubular welded frame scaffold was braced by cross, horizontal or diagonal braces, or combination thereof, to ensure that the scaffold was plumb, level, and square. Two instances were noted where scaffolds were erected without braces. Scaffolds were positioned on a grassy surface. This condition exposed employees to fall hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0