BRIDGEPORT, CT ·
OSHA Inspection: CONNECTICUT PLATE & ART GLASS CO., INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CONNECTICUT PLATE & ART GLASS CO., INC in 1751 MAIN ST., BRIDGEPORT, CT 06604 (NAICS 238150). OSHA activity number 340034180.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONNECTICUT PLATE & ART GLASS CO., INC
- Site address
- 1751 MAIN ST.
- City
- BRIDGEPORT
- State
- CT
- ZIP
- 06604
- Mailing
- 1751 MAIN ST., BRIDGEPORT, CT 06604
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238150
- Employees
- 6
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.132 D01
- Issued
- Jan 22, 2015
- Abate by
- Mar 18, 2015
- Penalty
- Initial $1,200 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment: ESTABLISHMENT: The employer did not assess the workplace to determine if hazards were present or likely to be present which necessitated the use of personal protective equipment (PPE).
Recent events (2)
- · I (S) $1000
- · Z (S) $1200
1910.132 F01
- Issued
- Jan 22, 2015
- Abate by
- Mar 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: ESTABLISHMENT: The employees, required to wear personal protective equipment (PPE) were not trained in the Workplace Hazard Assessment pertaining to the use and maintenance of personal protective equipment (PPE).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.141 A04 I
- Issued
- Jan 22, 2015
- Abate by
- Feb 3, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1910.141(a)(4)(i): Receptacle(s) used for putrescible solid or liquid waste or refuse were not constructed to prevent leaks and were not thoroughly cleaned and maintained in a sanitary condition: ESTABLISHMENT: A commode used by employees was not maintained in a clean condition and was not secured to the floor.
Recent events (2)
- · I (S) $1200
- · Z (S) $1200
1910.304 G06 VI
- Issued
- Jan 22, 2015
- Abate by
- Feb 3, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.304(g)(6)(vi): Exposed noncurrent-carrying metal parts of cord- and plug-connected equipment that could have become energized were not grounded: ESTABLISHMENT: The attachment plug of the flexible cord of the Sommer & Maca Wet Sanding machine was missing a grounding pin.
Recent events (2)
- · I (S) $2000
- · Z (S) $2000
1910.305 A02 X
- Issued
- Jan 22, 2015
- Abate by
- Feb 3, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. ESTABLISHMENT: The orange flexible extension cord, used to power a Milwaukee Miter Saw was not protected from accidental damage where it was concealed behind the saw, went through rolled paper, around the concrete block corner, over broken glass and then was plugged into the electrical outlet box.
Recent events (2)
- · I (S) $0
- · Z (S) $2000
1910.305 B02
- Issued
- Jan 22, 2015
- Abate by
- Feb 3, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: ESTABLISHMENT: An electrical outlet box, used to power a Milwaukee Miter saw, was missing a faceplate.
Recent events (2)
- · I (S) $0
- · Z (S) $2000
1910.305 E02
- Issued
- Jan 22, 2015
- Abate by
- Feb 3, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(e)(2): Switches, circuit breakers and switchboards installed in wet locations were not enclosed in weatherproof enclosures: ESTABLISHMENT: The metal electrical switch box of Sommer & Maca Wet Sanding machine was not enclosed in a waterproof enclosure.
Recent events (2)
- · I (S) $0
- · Z (S) $2000
1910.305 G02 III
- Issued
- Jan 22, 2015
- Abate by
- Feb 3, 2015
- Penalty
- Initial $2,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: ESTABLISHMENT: The outer sheathing of the flexible cord of the Sommer & Maca Wet Sanding machine was pulled away from the fitting of the attachment and was not provided with appropriate tension relief protection.
Recent events (2)
- · I (S) $0
- · Z (S) $2000
More inspections in this industry (NAICS 238150)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340034180.