LANCASTER, NY —
OSHA Inspection: ADVANCED THERMAL SYSTEMS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ADVANCED THERMAL SYSTEMS, INC. in 15 ENTERPRISE DRIVE, LANCASTER, NY 14086 (NAICS 332919). OSHA activity number 340035609.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADVANCED THERMAL SYSTEMS, INC.
- Site address
- 15 ENTERPRISE DRIVE
- City
- LANCASTER
- State
- NY
- ZIP
- 14086
- Mailing
- 15 ENTERPRISE DR., LANCASTER, NY 14086
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332919
- Employees
- 33
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.106 E06 II
- Issued
- Dec 18, 2014
- Abate by
- Mar 13, 2015
- Penalty
- Initial $2,380 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with. a) On or about, 10/27/14, in the loading dock area employees were dispensing flammables, such as but not limited to: Acetone from a 55 gallon drum to a safety container without the use of bonding straps to control static electricity. b) On or about, 10/27/14, in the spray booth area, bonding and grounding procedures were not used while employees were transferring flammable paints such as, Shopcoat Primer, Red Oxide and Heat Flex Hi-Temp 1200, Gray from container to spray gun to control static electricity. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $2380
1910.147 C06 I
- Issued
- Dec 18, 2014
- Abate by
- Jan 13, 2015
- Penalty
- Initial $2,380 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed. a) On or about 10/27/14, in the establishment, the employer did not conduct periodic inspections of their energy control procedures(Lockout/Tagout) at least annually for machines such as, but not limited to: CNC Machines: Doosan Puma 400m, Mori Seike Dura Turn 2550, Puma 280L, HAAS VOP-A. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $2380
1910.147 C07 I A
- Issued
- Dec 18, 2014
- Abate by
- Jan 13, 2015
- Penalty
- Initial $2,380 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control. a) On or about, 10/27/14, in the establishment, the employer did not provide authorized employee Lockout/Tagout (LOTO) training to employees performing maintenance activities such as, but not limited to: changing drill bites on CNC machines, cleaning machines, changing dies on presses and changing chucks on the lathes. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $2380
1910.212 A01
- Issued
- Dec 18, 2014
- Penalty
- Initial $2,023 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc. a) On or about, 10/27/14, in the plant, machine guards were not provided to protect operators and other employees from hazards created by exposed rotating parts from the lathes machines. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2023
1910.303 F02
- Issued
- Dec 18, 2014
- Abate by
- Jan 13, 2015
- Penalty
- Initial $1,785 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident. a) On or about 10/27/14, in the plant, a circuit breaker panel was missing index card to tell employees what circuit breaker to turns off for each machine in time of an emergency or for servicing/maintenance of machines. b) On or about 10/27/14, in the plant, disconnect switches located in the table saw area and the CNC area were not marked to indicate the machines that they controlled. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (S) $1785
1910.37 B04
- Issued
- Dec 18, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): If the direction of travel to the exit or exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction of travel to the nearest exit and exit discharge. Additionally, the line-of-sight to an exit sign must clearly be visible at all times. a) On or about, 10/27/14 in the office area signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Advanced Thermal Systems, INC.
View Advanced Thermal Systems, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332919)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340035609.