OSHA Inspection: GARDEN STATE BRICKFACE WINDOWS & SIDING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GARDEN STATE BRICKFACE WINDOWS & SIDING in 2831 AMBOY RD., STATEN ISLAND, NY 10306 (NAICS 238140). OSHA activity number 340040864.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Garden State Brickface Windows & Siding — free Get an email when a new federal OSHA severe-injury report for Garden State Brickface Windows & Siding is published. One employer, no account, unsubscribe in one click.
Site address
2831 AMBOY RD.
City
STATEN ISLAND
State
NY
ZIP
10306
Mailing
217 HIGHLAND PARKWAY, ROSELLE, NJ 07203
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
12
Ownership type
A

12 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $4,620 · Current $4,620
29 CFR 1926.100(a): Employees working in areas where there was possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets.   a) 2831 Amboy Rd., Staten Island, NY: Employees not wearing protective helmets working on the ground beneath siding work being performed overhead were exposed to struck-by hazards.    Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $4620

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $3,850 · Current $3,850
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents.   a)  2831 Amboy Rd., Staten Island, NY:  Employees not wearing eye and or face protection to prevent them from incurring eye and face injuries from flying debris were observed using power operated hand tools including but not limited to: a drill, circular saw and sawzall preparing and manipulating siding materials during the siding installation operation.     Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $3850

1926.416 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $5,390 · Current $5,390
29 CFR 1926.416(a)(1):  Employer permitted an employee to work in such proximity to part of an electric power circuit that the employee could contact the electric power circuit in the course of work, without ensuring that the employee was protected against electric shock by de-energizing the circuit and grounding it or by guarding it effectively by insulation or other means.   a) 2831 Amboy Rd., Staten Island, NY: Employees performing a siding installation operation were working from a scaffold were within approximately 3 feet of the electrical service feeder connection and lines supplying power to the residence; employees were exposed to electrocution hazards.       Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $5390

1926.416 A03

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(3): Before work is begun the employer did not ascertain by inquiry or direct observation, or by instruments, whether any part of an energized electric power circuit, exposed or concealed, was so located that the performance of the work may bring any person, tool, or machine into physical or electrical contact with the electric power circuit. The employer did not post and maintain proper warning signs where such a circuit exists. The employer did not advise employees of the location of such lines, the hazards involved, and the protective measures to be taken.  a) 2831 Amboy Rd., Staten Island, NY:  An employee was exposed to an electrocution hazard working on top of a scaffold platform conducting a siding installation operation using hand tools including but not limited to metal shears that were in close proximity to the un-protective electrical service feeder connection and lines supplying power to the residence.    Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $0

1926.416 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $3,850 · Current $3,850
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables shall not be used.   2831 Amboy Rd., Staten Island, NY:  Employees were using a sawzall equipped with a cord that was frayed exposing the employees to shock hazards.   Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $3850

1926.451 F07

Serious Gravity 10 1 instance 4 exposed
Issued
Apr 22, 2015
Penalty
Initial $5,390 · Current $5,390
29 CFR 1926.451(f)(7): Scaffolds was not erected, moved, dismantled, or altered only under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Such activities shall be performed only by experienced and trained employees selected for such work by the competent person.   2831 Amboy Rd., Staten Island, NY:  Employees were using a wood scaffold that had not been erected by a competent person during a siding installation that was not fully planked, missing mid and end rails and toe boards.       Conditions were observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $5390

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolding was not fully planked or decked.   a) 2831 Amboy Rd., Staten Island, NY:  Employees performing siding operations from the platform on the upper level of a wood frame scaffold approximately 13 feet above the ground below were exposed to fall hazards.  The platform was not fully planked from front upright to the rear upright.   Condition was observed on or about October 27, 2014.
Recent events (1)
  • — Z (S) $0

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Cross braces were used as used as a means of access.   a) 2831 Amboy Rd., Staten Island, NY:  2831 Amboy Rd., Staten Island, NY:  Employees climbing the cross braces of the wood frame scaffold were exposed to fall hazards of approximately 13 feet to the ground below as a ladder was not provided for safe access to the scaffold work platform(s).   Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $0

1926.451 G04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:   a) 2831 Amboy Rd., Staten Island, NY:  Employees were exposed to fall hazards of approximately 13 feet while performing siding operations working from the top level of a wood frame scaffold that was missing mid and end-rails.    Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $0

1926.451 H02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.451(h)(2)(ii): A toeboard shall be erected along the edge of platforms more than 10 feet (3.1 m) above lower levels for a distance sufficient to protect employees below.     a) 2831 Amboy Rd., Staten Island, NY: Employees working on the ground level beneath the wood frame scaffold performing a siding installation were exposed to struck by hazards because a toeboard had not been installed on the top level platform.    Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.   a) 2831 Amboy Rd., Staten Island, NY:  Employees performing a siding operation were using a ladder to access the first level of the wood frame scaffold; the ladder was not secured and did not extend 3 feet above the platform.  Employees were exposed to fall hazards.      Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $3080

1926.1053 B04

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladders were not used only for the purpose for which they were designed.    a) 2831 Amboy Rd., Staten Island, NY:  Employees performing siding operations were exposed to falls using a folding ladder in lieu of a straight ladder to access the second level working platform of the wood frame scaffold.        Conditions observed on or about Oct. 27, 2014.
Recent events (1)
  • — Z (S) $0

View Garden State Brickface Windows & Siding's full OSHA safety record →