Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUN EDISON INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUN EDISON INC. in 501 PEARL DRIVE, SAINT PETERS, MO 63376 (NAICS 334413). OSHA activity number 340043066.

Watch SUN Edison INC. — free Get an email when a new federal OSHA severe-injury report for SUN Edison INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SUN EDISON INC.
Site address
501 PEARL DRIVE
City
SAINT PETERS
State
MO
ZIP
63376
Mailing
501 PEARL DRIVE, SAINT PETERS, MO 63376
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334413
Employees
850
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2550.00 · Current $1785.00 Reduced
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by:        a. Operation of Meyer Burger TS 205 and TS 207 saws without manufactured guard door interlocks, resulted in potential hazards of contact with the cutting blade and being struck by flying parts from a broken blade.    b. Cleaning the vacuum mechanism of the Meyer Burger TS 205 and TS 207 saws with the machines on (blade rotating) resulted in potential contact with the cutting blade and/or being struck by flying parts from a broken blade.    Abatement documentation is required for this violation.
Recent events (2)
  • — I (S) $1785
  • — Z (S) $2550

1910.303 G02 I

Serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $2550.00 · Current $1785.00 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a. The electrical cabinet door, which included electrical components at 460 V, to TS205 saw in the SPD Rod Lab was not closed and secured closed.    Abatement documentation is required for this violation.