FULTON, MO —
OSHA Inspection: UNITED CONSTRUCTION SOLUTIONS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of UNITED CONSTRUCTION SOLUTIONS in 217 SYCAMORE, FULTON, MO 65251 (NAICS 238160). OSHA activity number 340043272.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- UNITED CONSTRUCTION SOLUTIONS
- Site address
- 217 SYCAMORE
- City
- FULTON
- State
- MO
- ZIP
- 65251
- Mailing
- P.O. BOX 946, ARNOLD, MO 63010
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 7
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Dec 10, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. During roofing work on a two story apartment building at 217 Sycamore, on 10-28-14, not all employees were connected to a lanyard/lifeline. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (1)
- — Z (S) $2000
1926.503 A02 III
- Issued
- Dec 10, 2014
- Abate by
- Jan 26, 2015
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used. a. During roofing work on a two story apartment building at 217 Sycamore, on 10-28-14, where training certification (documentation) did not exist for the fall hazards and use of fall protection at this job site; there was also indication that employees did not understand that re-positioning was not a reason for being connected at all times. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (1)
- — Z (S) $1200
1926.503 B01
- Issued
- Dec 10, 2014
- Abate by
- Jan 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a. During roofing work on a two story apartment building at 217 Sycamore, on 10-28-14, training certification (documentation) did not exist for the fall hazards and use of fall protection at this job site. Abatement certification and abatement documentation is required for this violation. The documentation should include written verification of abatement, applicable measurements or monitoring results, and photographs or videos which you believe will be helpful. The abatement certification sheet is enclosed with the citation(s).
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238160)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340043272.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.