Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: GALINDO'S ALL CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GALINDO'S ALL CORP in 6-20 PLAZA ROAD, FAIR LAWN, NJ 07410 (NAICS 238140). OSHA activity number 340043504.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Galindo'S ALL Corp for free Get an email when a new federal OSHA severe-injury report for Galindo'S ALL Corp is published. One employer, no account, unsubscribe in one click.
Establishment
GALINDO'S ALL CORP
Site address
6-20 PLAZA ROAD
City
FAIR LAWN
State
NJ
ZIP
07410
Mailing
428 MAIN STREET, PASSAIC, NJ 07055
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
Private (A)

8 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) Building Exterior: An employee working without hard hat was exposed to a struck by hazard from five gallon bucket with stucco material and unsecured wooden plank, on or about 10/28/2014.
Recent events (1)
  • · Z (S) $2200

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii)   a) Building Exterior: Employees were working from a fabricated scaffold two frames in height that was not fully planked, on or about 10/28/2014.
Recent events (1)
  • · Z (S) $3080

1926.451 C02 II

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units:   a) Building Exterior:  A scaffold two frames in height was supported on a hollow cement block, on or about 10/28/2014.  b) Building Exterior:  A scaffold plank was supported on an extension ladder, on or about 10/28/2014.
Recent events (1)
  • · Z (S) $2200

1926.451 E01

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.      a) Building Exterior: Two employees were not provided a means to access the levels of a fabricated scaffold two frames in height, on or about 10/28/2014.       b) Building Exterior: Two employees were not provided a means to access an alum-a-pole pump jack scaffold, on or about 10/28/2014.
Recent events (1)
  • · Z (S) $2200

1926.451 E09 IV

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.451(e)(9)(iv): Cross braces on tubular welded frame scaffolds were used as a means of access or egress.   a) Building Exterior:  Employees were using the cross braces to access the levels of a fabricated scaffold three frames in height, on or about 10/28/2014.  b) Building Exterior:  Employees were using the cross braces to access the levels of a fabricated scaffold two frames in height, on or about 10/28/2014.
Recent events (1)
  • · Z (S) $2200

1926.451 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 17, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.  a) Building Exterior:  An employee was using a fabricated scaffold three frames in height approximately five (5) inches from energized electrical line, on or about 10/28/2014.
Recent events (1)
  • · Z (S) $3080

1926.451 G01

Serious Gravity 10 2 instances 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $3,080 · Current $3,080
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   a) Building Exterior: Two employees exposed to a 12 foot fall hazard while working from an alum-a-pole pump jack scaffold that was not equipped with a guardrail system or other means of fall protection in place, on or about 10/28/2014.     b) Building Exterior: Two employees exposed to a 12 foot fall hazard while working from fabricated scaffold two frames in height that did not have a guardrail system or other means of fall protection in place, on or about 10/28/2014.
Recent events (1)
  • · Z (S) $3080

1926.452 C02

Serious Gravity 5 2 instances 2 exposed
Issued
Dec 17, 2014
Penalty
Initial $2,200 · Current $2,200
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:    a) Building Exterior:  Scaffold two frames in height was missing cross, horizontal, or diagonal braces, on or about 10/28/2014.   b) Building Exterior:  Scaffold three frames in height was missing cross, horizontal, or diagonal braces, on or about 10/28/2014.
Recent events (1)
  • · Z (S) $2200

View Galindo'S ALL Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340043504.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.