Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: AARON DESIGN & BUILD, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AARON DESIGN & BUILD, INC. in 3937 LEGATION ST., NW, WASHINGTON, DC 20009 (NAICS 236118). OSHA activity number 340044213.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aaron Design & Build, INC. for free Get an email when a new federal OSHA severe-injury report for Aaron Design & Build, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3937 LEGATION ST., NW
City
WASHINGTON
State
DC
ZIP
20009
Mailing
5556 WICOMICO CIRCLE, NEW MARKET, MD 21774
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
4
Ownership type
Private (A)

5 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2014
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:   a)  Front Yard - On or about 10/27/2014, a worker was exposed to a struck-by hazard for he was not wearing eye protection while operating a pneumatic nail gun while attaching wooden trim to a porch soffit.
Recent events (1)
  • · Z (S) $1600

1926.304 F

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2014
Abate by
Jan 8, 2015
Penalty
Initial $2,000 · Current $2,000
29 CFR 1926.304(f): Other requirements. All woodworking tools and machinery did not meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery, in that:   a) Front Yard - On or about 10/27/2014, a spreader with which to protect carpenters wood trim and other materials fed into the saw from binding and being ejected, was not provided; which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 4.1.2(b).          Condition Corrected During Inspection.       b) Front Yard - On or about 10/27/2014, an anti-kickback device or dogs to protect carpenters wood  trim and other materials fed into the saw from binding and being ejected was not provided, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 4.1.2(e).    Condition Corrected During Inspection.            c) Front Yard - On or about 10/27/2014, a restart switch that would prevent the saw from unexpectedly restarting after a temporary interruption of power was not provided, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 3.1.3(c).            Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $2000

1926.304 I01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 11, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut:   a)  Front Yard - On or about 10/27/2014, A Bosch 10 in. portable table saw (serial no. 89224-1414) was not provided with a hood or top guard which would prevent the carpenter ripping wood trim from accidentally coming into contact with the saws rotating blade.
Recent events (1)
  • · Z (S) $0

1926.405 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 11, 2014
Abate by
Dec 31, 2014
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy:   a)  Front Yard - On or about 10/27/2014, carpenters were exposed to a 120 volt electrical contact hazard from a duplex outlet which was not provided with a faceplate.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (S) $1200

1926.405 G02 IV

Other-than-serious 2 instances 2 exposed
Issued
Dec 11, 2014
Abate by
Dec 31, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:   a)  Front Yard - On or about 10/27/2014, no strain relief was provided to a male attachment plugs used to power portable electric power tools.  b) Front Yard - On or about 10/27/2014, no strain relief was provided to a male attachment plugs used to power portable electric power tools.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340044213.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.