WASHINGTON, DC ·
OSHA Inspection: AARON DESIGN & BUILD, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AARON DESIGN & BUILD, INC. in 3937 LEGATION ST., NW, WASHINGTON, DC 20009 (NAICS 236118). OSHA activity number 340044213.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AARON DESIGN & BUILD, INC.
- Site address
- 3937 LEGATION ST., NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20009
- Mailing
- 5556 WICOMICO CIRCLE, NEW MARKET, MD 21774
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1926.102 A01
- Issued
- Dec 11, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Front Yard - On or about 10/27/2014, a worker was exposed to a struck-by hazard for he was not wearing eye protection while operating a pneumatic nail gun while attaching wooden trim to a porch soffit.
Recent events (1)
- · Z (S) $1600
1926.304 F
- Issued
- Dec 11, 2014
- Abate by
- Jan 8, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.304(f): Other requirements. All woodworking tools and machinery did not meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery, in that: a) Front Yard - On or about 10/27/2014, a spreader with which to protect carpenters wood trim and other materials fed into the saw from binding and being ejected, was not provided; which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 4.1.2(b). Condition Corrected During Inspection. b) Front Yard - On or about 10/27/2014, an anti-kickback device or dogs to protect carpenters wood trim and other materials fed into the saw from binding and being ejected was not provided, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 4.1.2(e). Condition Corrected During Inspection. c) Front Yard - On or about 10/27/2014, a restart switch that would prevent the saw from unexpectedly restarting after a temporary interruption of power was not provided, which is a requirement of the American National Standards Institute, 01.-1961, Safety Code for Woodworking Machinery, Section 3.1.3(c). Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $2000
1926.304 I01
- Issued
- Dec 11, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular hand-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) Front Yard - On or about 10/27/2014, A Bosch 10 in. portable table saw (serial no. 89224-1414) was not provided with a hood or top guard which would prevent the carpenter ripping wood trim from accidentally coming into contact with the saws rotating blade.
Recent events (1)
- · Z (S) $0
1926.405 B02
- Issued
- Dec 11, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.405(b)(2): In energized installations, each outlet box did not have a cover, faceplate, or fixture canopy: a) Front Yard - On or about 10/27/2014, carpenters were exposed to a 120 volt electrical contact hazard from a duplex outlet which was not provided with a faceplate. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $1200
1926.405 G02 IV
- Issued
- Dec 11, 2014
- Abate by
- Dec 31, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Front Yard - On or about 10/27/2014, no strain relief was provided to a male attachment plugs used to power portable electric power tools. b) Front Yard - On or about 10/27/2014, no strain relief was provided to a male attachment plugs used to power portable electric power tools. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.