MANCHESTER, NH —
OSHA Inspection: BRADY SULLIVAN PAYROLL MANAGEMENT, INC.
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of BRADY SULLIVAN PAYROLL MANAGEMENT, INC. in 195 MCGREGOR ST., MANCHESTER, NH 03101 (NAICS 236118). OSHA activity number 340045533.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BRADY SULLIVAN PAYROLL MANAGEMENT, INC.
- Site address
- 195 MCGREGOR ST.
- City
- MANCHESTER
- State
- NH
- ZIP
- 03101
- Mailing
- 670 N. COMMERCIAL ST. SUITE 303, MANCHESTER, NH 03101
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.20 B02
- Issued
- Dec 19, 2014
- Abate by
- Dec 26, 2014
- Penalty
- Initial $4,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): a. Site Employees and subcontractors performing siding building renovations were not protected from hazards associated with tripping hazards, electrical hazards, and insufficient means of egress when the employer failed to initiate a program that would provide for frequent and effective inspections of the jobsite in order to identify and correct hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $4400
1926.25 A
- Issued
- Dec 19, 2014
- Penalty
- Initial $3,300 · Current $1,650 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a. 2nd floor stairway landing - Employees and subcontractors were not provided with clear and unobstructed exit routes when discarded floor boards and other debris were stored in a stairway.
Recent events (2)
- — I (S) $1650
- — Z (S) $3300
1926.1051 A
- Issued
- Dec 19, 2014
- Abate by
- Dec 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a. Site - Employees and subcontractors were not protected from falls of approximately 26 inches when a pair of bay doors were used as entry and exit ways to the building but were not equipped with stairs or other means of access.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.403 I02 I
- Issued
- Dec 19, 2014
- Abate by
- Dec 26, 2014
- Penalty
- Initial $4,400 · Current $1,650 Reduced
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a. 2nd floor hallway - Employees and subcontractors were not protected from electrical hazards where multiple units on the temporary lighting string were left unguarded and without bulbs.
Recent events (2)
- — I (S) $1650
- — Z (S) $4400
1926.405 A02 II E
- Issued
- Dec 19, 2014
- Abate by
- Dec 26, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a. 2nd floor hallway - Employees and subcontractors were not protected from electrical hazards and lacerations from broken light bulbs when multiple bulbs on the temporary lighting string were left unprotected.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Brady Sullivan Payroll Management, INC.
View Brady Sullivan Payroll Management, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236118)
More inspections in NH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340045533.