OSHA Inspection: TYLER BUILDING SYSTEMS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TYLER BUILDING SYSTEMS in 3535 SHILOH ROAD, TYLER, TX 75707 (NAICS 332311). OSHA activity number 340047810.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Tyler Building Systems — free Get an email when a new federal OSHA severe-injury report for Tyler Building Systems is published. One employer, no account, unsubscribe in one click.
Site address
3535 SHILOH ROAD
City
TYLER
State
TX
ZIP
75707
Mailing
3535 SHILOH ROAD, TYLER, TX 75707
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332311
Employees
60
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 24, 2014
Abate by
Jan 7, 2015
Penalty
Initial $4,900 · Current $4,900
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.    This violation was discovered on or about October 29, 2014; where employees in the maintenance department and machine operators were required to perform service and routine maintenance work on machines and equipment.  The employer had not developed energy control procedures.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $4900

1910.147 C06 I C

Serious Gravity 10 1 instance 5 exposed
Issued
Dec 24, 2014
Abate by
Jan 7, 2015
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected:    This violation was discovered on or about October 29, 2014; where employees in the maintenance department and machine operators were required to perform service and routine maintenance work on machines and equipment, but the employer did not periodically review the energy control procedures to determine their effectiveness.