NEW YORK, NY —
OSHA Inspection: MRMD NY CORP
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MRMD NY CORP in 155 WEST 125TH STREET, NEW YORK, NY 10040 (NAICS 238190). OSHA activity number 340050491.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MRMD NY CORP
- Site address
- 155 WEST 125TH STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10040
- Mailing
- 3041 AVE U, BROOKLYN, NY 11229
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 25
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.404 B01 II
- Issued
- Dec 2, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. On or about October 30, 2014 and October 31, 2014 Location: 155 West 126th Street, NY NY, 4th floor east side of stairs. Employees were utilizing a temporary electrical outlet box to energize portable power tools, that was not protected from ground fault electrical shorts, because the temporary wiring system was not protected by a ground fault circuit interrupter.
Recent events (1)
- — Z (S) $2000
1926.405 J01 II
- Issued
- Dec 2, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.405(j)(1)(ii): Fixtures, lampholders, rosettes, or receptacles were not securely supported: On or about October 30, 2014 LOCATION: 155 West 126th Street, New York, NY, west stairway on fourth floor. a). Employees were using a temporary 1900 type, 4 inch square electric outlet box to energize power tools. The 1900 box was not properly secured to a permanent location.
Recent events (1)
- — Z (S) $1600
1926.501 B02 II
- Issued
- Dec 2, 2014
- Abate by
- Dec 12, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(2)(ii): Each employee on a walking/working surface 6 feet (1.8 m) or more above a lower level where leading edges are under construction, but who was not engaged in the leading edge work, was not protected from falling by a guardrail system, safety net system, or personal fall arrest system.Note: If a guardrail system was chosen to provide the fall protection, and a controlled access zone had already been established for leading edge work, the control line may be used in lieu of a guardrail along the edge that parallels the leading edge. On or about October 30, 2014 and October 31, 2014 A). Employees were exposed to fall hazards in excess of 10 feet to the lower level because they were not protected from falling by means of Personal Fall Arrest System, Guardrails, Safety Nets or Controlled access zone. B). Employees entering and exiting the job site were exposed to falls to the basement due to floor sheathing being removed exposing the floor joists and the basement below.
Recent events (1)
- — Z (S) $2800
1926.1052 B01
- Issued
- Dec 2, 2014
- Abate by
- Dec 12, 2014
- Penalty
- Initial $2,400 · Current $2,400
General-duty citation text
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.Temporary treads and landings used for pan stairs that were to be filled in with concrete or other solid material at a later date were worn below the level of the top edge of the pan. On or about October 30, 2014 and October 31, 2014 Location: 155 West 126th Street, New York, NY every stair well throughout the project. Employees were traversing throughout the project using stairwells and were exposed to trip and fall hazards because the stair landing pans were not filled in with a solid material and the material used to fill stair treads had been worn down below the top lip of the tread pan.
Recent events (1)
- — Z (S) $2400
1926.1052 C01
- Issued
- Dec 2, 2014
- Abate by
- Dec 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a handrail system along each unprotected side or edge: On or about October 30, 2014, and again on October 31, 2014. Location: 155 West 126th Street, New York, NY a). Employees working on site traversed the west stairs from roof top to street level numerous times daily to complete their work. Employees were exposed to fall hazards because the stair systems was not equipped with a handrail system along each unprotected side or edge of the stairs.
Recent events (1)
- — Z (S) $0
1926.1052 C04
- Issued
- Dec 2, 2014
- Abate by
- Dec 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1052(c)(4): Employer did not ensure Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were provided between the top rail of the stair rail system and the stairway steps: On or about October 30, 2014, and again on October 31, 2014. Location; 155 West 126th Street, New York, NY West structure fourth floor stairway. a). Employees utilizing stairs to traverse through the project from ground level to the roof, were not protected from falls off the stairs because the stairwells were not protected with midrails, screens, mesh, or intermediate vertical members.
Recent events (1)
- — Z (S) $0
More inspections at Mrmd NY Corp
View Mrmd NY Corp's full OSHA safety record →
More inspections in this industry (NAICS 238190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340050491.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.