OSHA Inspection: CONDESA RESTAURANT, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CONDESA RESTAURANT, INC. in 1003 N. ASHLAND AVE., CHICAGO, IL 60622 (NAICS 722310). OSHA activity number 340050921.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Condesa Restaurant, INC. for free Get an email when a new federal OSHA severe-injury report for Condesa Restaurant, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1003 N. ASHLAND AVE.
City
CHICAGO
State
IL
ZIP
60622
Mailing
1003 N. ASHLAND AVE., CHICAGO, IL 60622
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
722310
Employees
20
Ownership type
Private (A)

4 citations on file for this inspection.

1903.19 C01

Other-than-serious 1 instance 5 exposed
Issued
Nov 19, 2015
Abate by
Jan 8, 2016
Penalty
Initial $400 · Current $400
29 CFR 1903.19(c)(1): Within 10 calendar days after the abatement date, the employer must certify to OSHA (the Agency) that each cited violation has been abated, except as provided in paragraph (c)(2) of this section.  a. On or about November 12, 2015 - the employer did not certify to OSHA within 10 days after the abatement date that each of the following cited violations issued had been corrected:  Citation Number            Item Number            Abatement Date 01                                001                       04/28/2015 01                                002a                      04/28/2015  01                                002b                      04/28/2015
Recent events (1)
  • · Z (O) $400

1910.23 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 2, 2015
Abate by
Apr 28, 2015
Penalty
Initial $2,400 · Current $2,400
29 CFR 1910.23(a)(1): Every stairway floor opening shall be guarded by a standard railing constructed in accordance with paragraph (e) of this section. The railing shall be provided on all exposed sides (except at entrance to stairway). For infrequently used stairways where traffic across the opening prevents the use of fixed standard railing (as when located in aisle spaces, etc.), the guard shall consist of a hinged floor opening cover of standard strength and construction and removable standard railings on all exposed sides (except at entrance to stairway).  Back Staircase - On or about October 30, 2014, a standard railing was not provided on a six to eight (6 - 8) foot platform that accessed stairs leading into the basement, located next to a delivery door, thereby exposing employees to fall injuries.
Recent events (1)
  • · Z (S) $2400

1910.24 C

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 2, 2015
Abate by
Apr 28, 2015
Penalty
Initial $2,400 · Current $2,400
29 CFR 1910.24(c): "Stair strength." Fixed stairways shall be designed and constructed to carry a load of five times the normal live load anticipated but never of less strength than to carry safely a moving concentrated load of 1,000 pounds.  Back staircase - On or about October 30, 2014, the employer failed to provide its employees with stable stairs that do not move when accessing the basement, thereby exposing employees to six (6) to eight (8) foot falls.
Recent events (1)
  • · Z (S) $2400

1910.24 H

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 2, 2015
Abate by
Apr 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.24(h): "Railings and handrails." Standard railings shall be provided on the open sides of all exposed stairways and stair platforms. Handrails shall be provided on at least one side of closed stairways preferably on the right side descending. Stair railings and handrails shall be installed in accordance with the provisions of 1910.23.  Back Staircase - On or about October 30, 2014, the employer failed to provide a standard railing to protect employees from falling, thereby exposing employees to six (6) to eight (8) foot falls and multiple injuries.