TAMPA, FL —
OSHA Inspection: A&A ELECTRIC SERVICES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of A&A ELECTRIC SERVICES, INC. in 3605 E. BOUGAINVILLEA AVE., TAMPA, FL 33612 (NAICS 238210). OSHA activity number 340050988.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A&A ELECTRIC SERVICES, INC.
- Site address
- 3605 E. BOUGAINVILLEA AVE.
- City
- TAMPA
- State
- FL
- ZIP
- 33612
- Mailing
- 4409 N. THATCHER AVE., TAMPA, FL 33614
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 13
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.303 E
- Issued
- Nov 19, 2014
- Abate by
- Dec 2, 2014
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1910.303(e): The manufacturer's name, trademark, or other descriptive marking by which the organization responsible for the product may be identified was not placed on the electrical equipment that was used, nor were markings provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary: a) For the electrical panel located on the ground near the Stanleyville Flume ride at the Busch Gardens Park as observed on or about 10/29/2014, no markings, labeling, or any other identifiers were observed on the panel.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.303 F02
- Issued
- Nov 19, 2014
- Abate by
- Dec 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: a) For the electrical panel lying on the ground near the Stanleyville Flume ride at Busch Gardens Theme Park in Tampa, FL, as observed on or about 10/29/2014, branch circuit labeling on the panel for overcurrent devices (circuit breakers) was illegible and/or missing. b) For the electrical panel on a block wall near the Gwazi Plaza area, as observed on or about 10/29/2014, overcurrent devices (circuit breakers) were incorrectly and/or illegibly labeled.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.304 F01 I
- Issued
- Nov 19, 2014
- Abate by
- Dec 2, 2014
- Penalty
- Initial $1,020 · Current $612 Reduced
General-duty citation text
29 CFR 1910.304(f)(1)(i): Conductors and equipment were not protected from overcurrent: For the Busch Gardens Theme Park, as observed on or about 10/29/2014, employees of A&A Electric accessed and/or worked around circuits that did not have overcurrent protection, in that, 20A receptacles and 25A flexible electrical cords were placed in circuit with 30A circuit breakers for the following locations: a) For the 20A receptacles and electrical cords at the Gwazi Plaza area near the Taco Bus that were in circuit with 30A breakers in a gift shop. b) For the 20A receptacles/woodheads and electrical cords at the service cart near the Crown Colony Steps that were in circuit with 30A breakers. c) For the 20A receptacles/woodheads in "The Experiment" scare house that were in circuit with 30A breakers.
Recent events (2)
- — I (S) $612
- — Z (S) $1020
1910.303 B02
- Issued
- Nov 19, 2014
- Abate by
- Dec 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For the Busch Gardens - Tampa, FL park, as observed on or about 10/29/2014, electricians accessed an electrical circuit breaker panel that was located outside in a horizontal position lying on the ground. The panel was not UL tested/rated to be installed in a horizontal position.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 J02 VI
- Issued
- Nov 19, 2014
- Abate by
- Dec 2, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(vi): A receptacle installed in a wet location where the product intended to be plugged into it was not to be attended while in use (for example, sprinkler system controllers, landscape lighting, and holiday lights) did not have an enclosure that was weatherproof with the attachment plug cap inserted or removed: a) For the Busch Gardens Park in Tampa, FL as observed on or about 10/29/2014, 20A and 50A outlets were installed outside in areas where they would be exposed to rain and weather. They were observed to not be attended while they were plugged/in use and did not have weatherproof enclosures that could close while a plug was inserted in the outlet.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at A&A Electric Services, INC.
View A&A Electric Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340050988.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.