WASHINGTON, DC ·
OSHA Inspection: AMILCAR MARTINEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AMILCAR MARTINEZ in 818 C STREET, SE, WASHINGTON, DC 20003 (NAICS 236118). OSHA activity number 340051085.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMILCAR MARTINEZ
- Site address
- 818 C STREET, SE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20003
- Mailing
- 5100 BUCHANAN STREET, HYATTSVILLE, MD 20781
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.20 B01
- Issued
- Nov 24, 2014
- Abate by
- Dec 19, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part: a) Job Site - The employer had not developed or implemented a safety and health program as evidenced by hazards such as but not limited to; portable fire extinguishers not provided where gasoline operated equipment was in use, fall protection not used when working 10' above ground and electrical hazards , on or about 10/16/2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $1600
1926.21 B02
- Issued
- Nov 24, 2014
- Abate by
- Dec 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) Job Site - Employees were not provided hazard recognition training as evidenced by hazards such as but not limited to; no portable fire extinguishers provided where employees were operating gasoline powered tools and employees were exposed to live electrical parts, 120 volts, 100 amp, in an open temporary service panel, on or about 10/16/2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $0
1926.150 C01 IV
- Issued
- Nov 24, 2014
- Abate by
- Dec 1, 2014
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.150(c)(1)(iv): There was not at least one fire extinguisher located adjacent to stairways on each floor of a multistory building: a) First Floor - A laborer was observed cutting steel rebar with a Stihl gasoline powered chop saw and there was no portable fire extinguisher available in the event of a fire, on or about 10/16/2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $1600
1926.405 B01
- Issued
- Nov 24, 2014
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.405(b)(1): Unused openings in cabinets, boxes, and fittings were not effectively closed: a) First Floor - Employees were turning on and off temporary lighting from a circuit breaker located inside a temporary service panel and six circuit breakers were missing, exposing employees to live electrical parts, 120 volt, 100 amp service, on or about, 10/16/2014.
Recent events (1)
- · Z (S) $2000
1926.501 B13
- Issued
- Nov 24, 2014
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Back Porch - A laborer was observed standing at the edge of a concrete deck while cutting steel rebar with a Stihl chop saw, model number TS420, and exposed to a 10 ft. fall hazard, on or about 10/16/2014. b) First Floor East Wall - Laborers were observed walking near open floor holes measuring between 4 ft., and 2 ft., wide and exposed to a 10 ft. fall, on or about 10/16/2014. c) First Floor at Temporary Service Panel - Laborers and foreman were observed near a floor hole that measured 22 inches by 48 inches and exposed to a 10 ft. fall hazard, on or about 10/16/2014.
Recent events (1)
- · Z (S) $2800
1926.503 A01
- Issued
- Nov 24, 2014
- Abate by
- Dec 12, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) Job Site - A fall protection training program was not provided for employees as evidenced by fall hazards such as but not limited to; floor holes through out the first floor and an open deck, 10' high on or about 10/16/2014. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $0
1926.404 B01 I
- Issued
- Nov 24, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) First Floor - A laborer was observed using a Bosch portable electric circular saw to cut a piece of plywood for a floor hole cover and not provided with a ground fault circuit interrupter, 120 volt, 15 amp service, on or about 10/16/2014.